Code
32
Different SD card
between download
interruption and
download resumption
33
Incorrect version data in
the SD card
34
Module error - Correct
module (destination) is
not in the SD card.
35
Module error – Module
in the SD card is not for
this machine
36
Module error –
The machine does not
have the program that
you are trying to
download.
38
Program version is not
allowed to update
40
Engine module
download failed
44
Controller module
download failed (access
error)
49
Firmware update is
prohibited
160
Meaning
• Setting the SD card was interrupted. Cycle the machine
off/on.
• If the update cannot be made even if you insert the correct
SD card, there is a possibility that the SD card is broken.
Retry again with a different SD card.
• If you cannot resolve the problem with the above steps,
replace the controller board.
• If the program is in the SD card, reinsert the SD card.
• If you updated engine, FCU, or operating unit, replace
each board.
• Acquire correct update data then install again.
• Acquire the correct data (Japan, Overseas, OEM, etc.)
then install again.
• Acquire correct update data then install again.
• Install the correct program in advance.
• Make sure SD card inserted correctly.
• If the update cannot be made even if you insert the correct
SD card, there is a possibility that the SD card is broken.
Retry again with a different SD card.
• Acquire correct update data then install again.
• Cycle the machine off/on.
• If the download failed again, replace the controller board.
• Cycle the machine off/on.
• If the program is in the SD card, replace the SD card.
• If the program is in the controller board, replace the
controller board.
• Firmware update is disabled in the administrator settings.
Retry by changing the settings to allow firmware update.