Inspection / Measurement
1. Inspect the rotor assembly.
Test the rotor for an open circuit by using the
ohmmeter (1). Replace the rotor if necessary.
YAD1E550
Test the rotor for open or short circuit (2).
Desciption
The measured
resistance
Replace the rotor if necessary.
Test the rotor for open or ground circuit by using
the ohmmeter (3). Replace the rotor if necessary.
YAD1E560
2. Inspect the stator.
Test the stator for an open circuit by using the
ohmmeter (1). Replace the stator if necessary.
YAD1E570
Test the stator for open or ground circuit by
using the ohmmeter (2). Replace the starter if
necessary.
YAD1E580
ENGINE ELECTRICAL 1E-25
Limit
2.9 Ω