SSANGYONG Y200
Inspection / Measurement
1. Inspect the rotor assembly.
•
Test the rotor for an open circuit by using the
ohmmeter (1). Replace the rotor if necessary.
YAD1E550
•
Test the rotor for open or short circuit (2).
Desciption
The measured
resistance
•
Replace the rotor if necessary.
•
Test the rotor for open or ground circuit by using
the ohmmeter (3). Replace the rotor if necessary.
YAD1E560
2. Inspect the stator.
•
Test the stator for an open circuit by using the
ohmmeter (1). Replace the stator if necessary.
YAD1E570
•
Test the stator for open or ground circuit by
using the ohmmeter (2). Replace the starter if
necessary.
YAD1E580
ENGINE ELECTRICAL 1E-25
Limit
2.9 Ω