Interfaces
4.8.2
Connection to encoders with 24V signal level (X3)
This interface can be used to operate the AX as a slave, mastered by an encoder with 24V signal
level (master-slave operation). The digital inputs DIGITAL-IN 1 and 2 at connector X3 must be
used. Frequency limit: 250 kHz, slew rate tv £ 0,1µs
AGND and DGND (connector X3) must be joined together !
4.8.3
Connection to a sine-cosine encoder (X1)
This interface can be used to operate the AX as a slave, mastered by a sine-cosine encoder
(master-slave operation). The connector X1 must be used. Encoder types with a power consump-
tion of more than 150mA can also be connected using our external power supply (ð p.89). For
encoders that do not have integrated terminating resistors, we offer an optional terminating adapter
(ð p. 89). Frequency limit: 250 kHz
AGND and DGND (connector X3) must be joined together !
52
02/06
AX2000
AX2000
- A.4.031.1/44,43
AX2000 Installation manual
BECKHOFF