4.6
Digital and analog inputs and outputs
4.6.1
Analog inputs (X3)
The servo amplifier is equipped with two differential inputs for analog setpoints which are
programmable. AGND (X3/1) must always be joined to the CNC-GND of the controls as a ground
reference.
Technical characteristics
—
—
—
—
—
—
Input Analog-In 1 (terminals X3/4-5)
Differential input voltage max. ± 10 V, resolution 14-bit, scalable
Standard setting : speed setpoint
Input Analog-In 2 (terminals X3/6-7)
Differential input voltage max. ± 10 V, resolution 12-bit, scalable
Standard setting : torque setpoint
Application examples for setpoint input Analog-In 2:
—
—
—
Fixing the direction of rotation
Standard setting : clockwise rotation of the motor shaft (looking at the shaft end)
—
—
To reverse the direction of rotation, swap the connections to terminals X3/4-5 and. X3/6-7 or
change the ROT. DIRECTION parameter in the "Speed controller" screen.
AX2000 Installation manual
Differential-input voltage max. ± 10 V
Resolution 1.25 mV
Ground reference AGND, terminal X3/1
Input resistance 20 kW
Common-mode voltage range for both inputs ± 10 V
Update rate 62,5 µs
AX2000
adjustable external current limit
reduced-sensitivity input for setting-up/jog operation
pre-control / override
Positive voltage between terminal X3/4 (+ ) and terminal X3/5 ( - ) or
Positive voltage between terminal X3/6 (+ ) and terminal X3/7 ( - )