Setup
5.4

Error messages

Errors which occur are shown in coded form by an error number in the LED display on the front
panel. All error messages result in the BTB/RTO contact being opened, and the output stage of the
amplifier being switched off (motor loses all torque). If a motor-holding brake is installed, it will be
activated.
Number
E / S / A / P Status Messages
* = These error messages can be cancelled by the ASCII command CLRFAULT, without executing a reset. If
only these errors are present, and the RESET button or the I/O-function RESET is used, the CLRFAULT com-
mand is also all that is carried out.
More information about faults and hints for removal can be found on page 92
62
Designation
Status Message
. . .
F01*
heat sink temperature
F02*
overvoltage
following error
F03*
feedback
F04
F05*
undervoltage
F06
motor temperature
aux. voltage
F07
F08*
overspeed
F09
EEPROM
F10
Flash-EPROM
F11
brake
motor phase
F12
F13*
internal temperature
F14
output stage
F15
I²t max
F16*
supply - BTB/RTO
F17
A/D converter
F18
regen
F19*
supply phase
Slot fault
F20
F21
Handling fault
Short circuit to earth
F22
(ground)
F23
CAN Bus off
F24
Warning
F25
Commutation error
F26
Limit switch
F27
AS-option
F28
reserved
Fieldbus-Sync
F29
F30
Emerg. Stop Timeout
F31
reserved
F32
System error
02/06
Explanation
Status messages, no error, see p. 60
updating the startup configuration
heat sink temperature too high
limit is set by manufacturer to 80°C (176°F)
overvoltage in DC bus link
limit depends on the mains supply voltage
message from the position controller
cable break, short circuit, short to ground
undervoltage in DC bus link
limit is set by manufacturer to 100V
motor temperature too high
limit is set by manufacturer to145°C (293°F)
internal aux. voltage not OK
motor running away, speed is too high
checksum error
checksum error
cable break, short circuit, short to ground
motor phase missing (cable break or similar)
internal temperature too high
fault in the output stage
I²t max. value exceeded
2 or 3 phases missing in the supply feed
error in the analog-digital conversion, usually caused by ex-
cessive EMI
regen circuit faulty or incorrect setting
a supply phase is missing
(can be switched off for 2-phase operation)
Hardware fault of the expansion card
Software fault of the expansion card
AX 640/670 only: short circuit to earth (ground)
CAN Bus total communication error
Warning displays as error
Encoder systems only
Homing error (hardware limit switch reached)
operational error with -AS- option, input for AS-Enable and
ENABLE have been set at the same time
reserved
Fieldbus not synchronized
Emerg. Stop Timeout
reserved
system software not responding correctly
AX2000 Installation manual