Power Supply Sincos; Terminating Adapter For Encoder Cables - Beckhoff AX2000 Assembly, Installation, Setup

Digital servo amplifier
Hide thumbs Also See for AX2000:
Table of Contents

Advertisement

BECKHOFF
6.3.5

Power Supply SINCOS

Technical Data
Output voltage
Output current
Protection type
Ambient temperature
Type of mounting
Cable length (amplifier -> mains supply)
Cable length (mains supply -> encoder)
6.3.6

Terminating adapter for encoder cables

Encoders that do not have integrated terminating resistors can be connected to X1 with our stan-
dard cables using this adapter.
The terminating resistors increase noise immunity. The adapter (approx. 200mm long) is connected
to the servo amplifier (X1).
AX2000 Installation manual
Expansions / Accessories
02/06
The extended power supply enables the
to servo amplifier
operation of encoder systems at connec-
(max. 2m)
tor X1 with a power consumption of up to
400mA DC. This power supply is
switched between X1 and the encoder
and supplied by AX2000.
The connection between the amplifier
and the power supply requires a 1:1 pro-
tected data cable with a maximum
length of 2m.
The encoder is connected to the power
supply using the normal encoder con-
nection cable (max. 50m).
to feedback
(max. 50m)
5V DC (-5%...+5%)
max. 400mA DC
IP20
0...+55°C
Mounting rail
max. 2m
max. 50m
89

Advertisement

Table of Contents
loading

Table of Contents