Power Supply Inputs - NEC Electra Elite IPK II General Description Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Table 5-5
AD(A)-R or AD(A)-2R Unit
ADA(2)-W Unit
AP(A)-R or AP(R)-R Unit
APA-U Unit or APR-U Unit
OPX(2)-U( ) ETU
SLI(4)/(8)-U( ) ETU
SLTII(1)-U( ) ADP

P
S
4
OWER
ECTION
The power supply inputs and the power consumption specifications for the Electra
Elite IPK II are listed below.
4.1
General Description Manual
Cable Connection Between the Analog Port and the Single Line
Equipment
Connected Equipment
Mixing digital and analog ports through the same 25-pair cable runs is not recommended.
Connected Equipment
Music on Hold and Background Music Sources
External Amplifier
ITH Cabling
R
EQUIREMENTS

Power Supply Inputs

The AC input (P64-U( ) PSU) requirements for the Electra Elite IPK II are listed
below:
117 Vac ± 10%
H
60 Hz ± 10%
H
Single Phase
H
7.5A circuit
H
A dedicated outlet, separately fused and grounded.
H
Cable
Twisted Pair
Twisted Pair
Twisted Pair
Twisted Pair
Twisted Pair
Twisted Pair
Twisted Pair
Table 5-6 Cabling Requirements
Document Revision 1
Maximum Feet from Connected
Equipment to Telephone
10 feet
10 feet
50 feet
50 feet
1,600 ohms
300 ohms
50 feet
Cable
Hi-Fi Shielded Audio Cable
Hi-Fi Shielded Audio Cable
Cat 5 Straight Data Network
Cable - 100 meters maximum
distance.
5 - 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents