Electra Elite IPK II
Table 3-3 Maximum System Capacities for Application Interface ETUs (Continued)
Application
Interface ETUs
PVA( )-U ETU as
K-CCIS – IP with
PVA
Note 1:
Refer to the KSU Power-Based Calculator Chart .
Note 2:
A maximum of three BSU(4M)/(2S)/(6S) DECT Wireless ETUs can be installed.
Note 3:
The IAD(8)-U( ) ETU is assigned as a CCISoIP ETU and counts as 8 trunk ports when installed with the IP CCH
ETU application loaded.
A maximum of one BSU(M) Master and two BSU(2S)/(6S) Slave ETUs can be
installed.
KSU P
S
2
ECTION
The Card Calculator on the next page allows you to determine the maximum power
consumption for the Power supply in each cabinet under the following conditions:
H
H
H
H
To calculate the two values (+5V and -24V) for a card:
General Description Manual
Description
For K-CCIS
-B
OWER
ASED
Each basic cabinet can contain a maximum of 10 cards.
Each expansion cabinet can contain a maximum of nine cards.
The total point value cannot exceed 1000 points for +5V.
The total point value cannot exceed 1000 points for -24V.
1.
Pick the card type in the chart below.
2.
Calculate the +5V total point value by multiplying the number of cards by
the +5V value in the chart.
3.
Calculate the -24V total point value by multiplying the number of cards by
the -24V value in the chart.
Maximum Capacities
Basic Port
Package
2
C
C
ALCULATOR
HART
Document Revision 1
Notes
Expanded
Port Package
11
3 - 13