Table 5-4 Electra Elite/D
Terminal or Adapter
DTU-8-1 TEL
DTP-8-1 TEL
DTU-8D-2 TEL
DTP-8D-1 TEL
DTU-16-1 TEL
DTP-16-1 TEL
DTU-16D-2 TEL
DTP-16D-1 TEL
DTP-16HC-1 TEL
DTU-32-1 TEL
DTP-32-1 TEL
DTU-32D-2 TEL
DTP-32D-1 TEL
DTR-2DT-1 TEL
DTR-4D-1 TEL
DTR-4R-1/2 TEL
DTH-4R-1/2 TEL
SLT(1)-U( ) ADP
DP-D-1
An AC Adapter is required for the DTP-16HC-1 TEL.
,
The length for the specified SLT Adapter is the length between the SLT Adapter and the ESI.
, ,
5 - 4
term
Series E Multiline Terminal Loop Resistance and Cable
Length
Maximum Loop
Resistance
(Ohms)
35
35
26
26
57
,
21
21
35
37
N/A
N/A
35
, ,
20
Maximum Feet by
Twisted 1-Pair Cable
24 AWG
600
600
450
450
1083
360
360
600
700
650
650
600
410
Electra Elite IPK II
Maximum Feet by
Twisted 2-Pair Cable
24 AWG
1000
1000
900
900
720
720
1000
1400
1000
1000
1000
820