Technical Data - ProMinent Pneumados PNDb Series Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

Pump type
Delivery output
at maximum
pressure
bar
l/h ml/ stroke
1000
10 0.76
1601
16
1.0
1602
16
1.7
1005
10
3.8
0708
7
6.3
0413
4
10.5
0220
2
16.7
1)
Suction height / suction pressure (dry) determined with clean as well as moistened valves, is tested with empty liquid end.
2)
Value corresponds to the obtainable vacuum compared to atmospheric pressure.
3)
Suction height / suction pressure tested with filled liquid end and filled suction line, provided sufficiently dimensioned
suction line cross-sections are given.
The delivery outputs were determined with an air hose length of 1m, using the Festo solenoid valve MHE3-M1H-3/2G-QS-6K,
as well as at max. stroke frequency (180 strokes/min.) and 100% stroke length, with pump at operating state temperature, test
medium water.
Compressed air filtered
Air consumption
for 1m line
Stroke frequency
Materials in contact
with medium, type
Liquid end
Suction/pressure
connection
Gaskets
Balls
Reproducibility,
metering accuracy
Permissible deviation of
the delivery output for all
material types
Permissible ambient
temperature
Perm. media temperature
Humidity:
Temperature:
ProMinent
®
3

Technical data

NOTE
Depending on the existing air pressure, the length of the pneumatic line and the layout of
the control, minor deviations in the delivery output may result.
Connection
Suction
size
height suction pressure height suction pressure pre-pressure
oØ • iØ
mm
0.07
6x4
0.09
6x4
0.16
6x4
0.35
8x5
0.58
8x5
0.97
8x5
1.55
12x9
6 bar ± 10%, filter size 40µm
47 I/min
max. 180 strokes/min
2)
Material no. 1.4571
®
DEVELOPAN
metering diaphragm with PTFE layer.
±2 given constant conditions, minimum backpressure 1 bar, stroke setting 30 – 100%, and
water-like medium for short time intervals
-5 % ...+ 15 %
-10 °C bis +50 °C
-5 °C bis +50 °C
Climate conditions for storage and transport:
< 95% relative humidity
-10 °C bis +50 °C
corresp.
3), 4)
2)
mWC
mbar
6
600
6
600
6
600
5
500
4
400
3
300
2
200
PV
PVDF
PVDF
PTFE
Ceramic
Suction
corresp.
1)
2)
mWC
mbar
2.0
200
2.8
280
3.0
300
3.0
300
2.0
200
2.5
250
2.0
200
SS...
Stainless steel
2)
2)
Stainless steel
PTFE
Ceramic
Technical data
Admissible
on suction side
bar
8
8
5.5
3
2
1.5
1
Page 7

Advertisement

Table of Contents
loading

Table of Contents