Installation

3.2.4 Space for servicing

3.3 Preparing for the installation

The dishwasher is designed to allow it to be positioned in a corner as shown in
the figure below. There must be a gap of at least 100 mm between the walls and
the dishwasher. A clearance of around 1 metre must be left in front of and to the
right of the dishwasher to allow access for servicing and maintenance. The
electrical cabinet can be swung out from the dishwasher when servicing and
repairs are needed. To facilitate this, clearance is needed in the form of a semi-
circle with a radius of around 0.75 m running from the front right-hand corner of
the machine, as shown in the figure below. If e.g. a loading table is to be
positioned next to the machine, this should be easy to move.
Dishwasher (seen from above) positioned next to a wall
Check that there is sufficient room for the dishwasher at the installation location
and that the ceiling is high enough for the machine with its hood open. Check that
there is sufficient room to transport the dishwasher to its installation location on
delivery. The machine's dimensions can be found in chapter "Technical data" on
page 63.
Make sure there is lifting equipment available which can handle the weight of the
dishwasher and that the floor where it is to stand is dimensioned for the weight of
the dishwasher when containing water, granules and the wash load. The ma-
chine's weight can be found in chapter "Technical data" on page 63.
Route connections for water and electricity.
Make sure there is a drain/waste pipe which is positioned as stated above.
In accordance with EN 61000-3-11, the machine is suitable for connecting to a
mains voltage with an impedance of Z
pedance must be determined in consultation with the relevant authority prior to
carrying out installation.
WD-90 DUO
1 m
=0.375 Ω or lower. The maximum im-
max
11
Rev. 1 (201702)