Danfoss VLT HVAC Basic Drive FC 101 Design Manual page 110

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

General Specifications
Frequency converter
Typical shaft output [kW]
Typical shaft output [hp]
Protection rating IP54
Maximum cable size in terminals (mains, motor)
[mm
2
(AWG)]
Output current
40 °C (104 °F) ambient temperature
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum input current
Continuous (3x380–440 V )[A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Maximum mains fuses
Estimated power loss [W], best case/typical
8
8
Weight enclosure protection rating IP54
[kg (lb)]
Efficiency [%], best case/typical
Output current - 50 °C (122 °F) ambient temperature
Continuous (3x380–440 V) [A]
Intermittent (3x380–440 V) [A]
Continuous (3x441–480 V) [A]
Intermittent (3x441–480 V) [A]
Table 8.8 3x380–480 V AC, 0.75–18.5 kW (1–25 hp), Enclosure Sizes I2–I4
1) Applies for dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/
vltenergyefficiency.
2) Efficiency measured at nominal current. For energy efficiency class, see chapter 8.4.12 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
108
®
VLT
HVAC Basic Drive FC 101
PK75
P1K5
0.75
1.5
1.0
2.0
I2
I2
4 (10)
4 (10)
2.2
3.7
2.4
4.1
2.1
3.4
2.3
3.7
2.1
3.5
2.3
3.9
1.8
2.9
2.0
3.2
21/
46/
1)
16
57
5.3
5.3
(11.7)
(11.7)
98.0/
97.7/
2)
97.6
97.2
1.93
3.7
2.1
4.07
1.8
3.4
2.0
3.7
Danfoss A/S © 04/2016 All rights reserved.
P2K2
P3K0
P4KO
P5K5
2.2
3.0
4.0
5.5
3.0
4.0
5.0
7.5
I2
I2
I2
I3
4 (10)
4 (10)
4 (10)
4 (10)
5.3
7.2
9.0
12.0
5.8
7.9
9.9
13.2
4.8
6.3
8.2
11.0
5.3
6.9
9.0
12.1
4.7
6.3
8.3
11.2
5.2
6.9
9.1
12.3
3.9
5.3
6.8
9.4
4.3
5.8
7.5
10.3
See chapter 8.3.1 Fuses and Circuit Breakers
46/
66/
95/
104/
58
83
118
131
5.3
5.3
5.3
7.2
(11.7)
(11.7)
(11.7)
(15.9)
98.3/
98.2/
98.0/
98.4/
97.9
97.8
97.6
98.0
4.85
6.3
7.5
10.9
5.4
6.9
9.2
12.0
4.4
5.5
6.8
10.0
4.8
6.1
8.3
11.0
P7K5
P11K
P15K
P18K
7.5
11
15
18.5
10.0
15
20
25
I3
I4
I4
I4
4 (10)
16 (6)
16 (6)
16 (6)
15.5
23.0
31.0
37.0
17.1
25.3
34.0
40.7
14.0
21.0
27.0
34.0
15.4
23.1
29.7
37.4
15.1
22.1
29.9
35.2
16.6
24.3
32.9
38.7
12.6
18.4
24.7
29.3
13.9
20.2
27.2
32.2
159/
248/
353/
412/
198
274
379
456
7.2
13.8
13.8
13.8
(15.9)
(30.4)
(30.4)
(30.4)
98.2/
98.1/
98.0/
98.1/
97.8
97.9
97.8
97.9
14.0
20.9
28.0
33.0
15.4
23.0
30.8
36.3
12.6
19.1
24.0
30.0
13.9
21.0
26.4
33.0
MG18C702

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt fc 101

Table of Contents