S E C T I O N T H R E E
Page 2 Configuration Options
IO preset
This options provides several QC system selections. All the necessary
RS-232 interface parameters are automatically set when a predefined I/O
preset is selected. A "CUSTOM" preset is available which allows you
manually set all available I/O options. Below is a chart that contains all
available I/O presets and their parameter settings.
NOTE: Certain parameters are mandatory for the I/ O preset and cannot be
changed. They are labeled with an "L" for locked. Other parameters are not
considered mandatory and are labeled with a "U" for unlocked. Finally,
parameters that remain unchanged from previous settings—and can be
changed—are shown as an asterisk (*).
I/O Preset
REPORT
SPRD-SHT
k:TNetA
k:TNetXT
K:C.A.P.
k:SYS25-75 Off (L)
f:TECOM
c:I/O#1
c:I/O#2
MITSY#1
MITSY#2
NORITSU
n:QSSnet
n:Micro
kn:Net
a:LC2000
CUSTOM
Windense
Kodatel
Sienna
k: (Kodak), f: (Fuji), c: (Copal), kn: (Konica), n: (Noritsu), a: (Agfa)
Page 2a Configuration Options
RCI (Remote Control Interface)
Controls the ability of the instrument to be operated remotely. Available
settings are: OFF, ON, TTL.
•
•
•
PIN5
Determines the status of the handshaking input on Pin 5 of the RS-232 I/O port.
Pin 5 may be interpreted as BUSY, CTS (clear-to-send), or OFF (ignored).
3-2
RCI
PIN5
XON
Off
*
*
*
*
*
Off (L)
Off (L)
Off (L)
Off (L)
CTS(L)
Off (L)
Off (L)
CTS(U)
Off (L)
CTS(L)
Off (L)
Off (L)
Off (L)
Off (U)
On (L)
Off (L)
Off (L)
On (U)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
Off (L)
Off (L)
On (U)
Off (L)
CTS(U)
Off (L)
Off (U)
Off (U)
Off (U)
*
*
*
TTL (U)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
#
#
#
On (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
OFF - sets the instrument into a receive mode at which time the instrument
receives data.
ON - enables data to be received via RCI command.
TTL (Time Tagged Log) - causes all data received into the serial port to be
placed into the log buffer with a time stamp.
DPT
COMP
ALF
DEL
On (L)
On (L)
On (U)
Off (L)
*
Off (L)
*
*
Off (L)
On (L)
On (L)
On (L)
Off (L)
On (L)
On (L)
Off (L)
Off (U)
On (U)
On (U)
Off (L)
Off (L)
On (L)
On (L)
Off (L)
Off (U)
Off (U)
Off (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
Off (U)
On (U)
On (U)
On (U)
Off (L)
Off(L)
Off(L)
Off (U)
Off (L)
Off(L)
Off(L)
Off (L)
Off (L)
On (L)
On (L)
Off (L)
Off (U)
Off (U)
Off (U)
Off (U)
*
*
*
*
Off (U)
On (U)
Off (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
#
#
#
#
Off (U)
On (U)
Off (U)
Off (U)
Off (U)
On (U)
Off (U)
Off (U)
On (U)
On (U)
On (U)
Off (U)
AXMT
BAUD
Off (U)
*
On (L)
*
On (L)
300(L)
On (L)
*
On (L)
9600(L)
On (L)
*
On (U)
1200(U)
On (L)
9600(L)
On (U)
9600(U)
On (U)
300(L)
On (L)
300(U)
On (L)
2400(U)
On (U)
2400(U)
*
*
Off (U)
2400(U)
On (U)
1200(U)
#
#
On (U)
9600 (U)
On (U)
9600 (U)
On (U)
4800 (U)
Need help?
Do you have a question about the 890 and is the answer not in the manual?