Page 1
Ci7XX0 Benchtop Spectrophotometer User Guide...
Page 3
Industry Canada Compliance Statement CAN ICES-3 (A) / NMB-3 (A) Equipment Information Use of this equipment in a manner other than that specified by X-Rite, Incorporated may compromise design integrity and become unsafe. WARNING: This instrument is not for use in explosive environments.
Page 5
S P E C T R O P H O T O M E T E R WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR APPLICATION, AND NON-INFRINGEMENT. NO EMPLOYEE OR AGENT OF X-RITE, OTHER THAN AN OFFICER OF X- RITE, IS AUTHORIZED TO MAKE ANY WARRANTY IN ADDITION TO THE FOREGOING.
Page 6
(order part number CIA-700-DVD). The source code is available from X-Rite for a period of three years after the last shipment of this product. Please direct all inquiries for source code to the following: Email: opensourcelicensing@xrite.com...
Page 7
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Copyright 2005 Trolltech AS Copyright 2007 Luca Barbato Copyright 2008 Aaron Plattner, NVIDIA Corporation Copyright 2008 Rodrigo Kumpera Copyright 2008 André...
Page 8
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Copyright (c) 1994, 1995 X Consortium, Inc. and Hewlett- Packard Company.
Page 9
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R This product uses software under the BSD license: Owner Package Version zlib...
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Table of Contents Overview Packaging Information Instrument Setup Powering the Instrument Sample Preview Method Front Panel Sample Shelf...
S P E C T R O P H O T O M E T E R OVERVIEW The Ci7XX0 is a reflectance / transmittance sphere benchtop spectrophotometer offering agreement with these X-Rite/GretagMacbeth instruments: 7000A, Color i7, and Color i5. The Ci7XX0 Spectrophotometer includes these features: •...
Your instrument packaging should contain all the items listed below. If any of these items are missing or damaged, contact X-Rite or your Authorized Representative. • Software box containing the Ci7XX0 Driver and Documentation CD along with any other optional software you may have ordered such as Color iControl and NetProfiler.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Sample Preview Method The instrument has three sample preview methods: Sample Door This method enables you to open the sample door and look at the sample position in the viewport.
Page 14
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Lens and Aperture Plate Indicators (*, 3.5, 6, 10, 17, 25) •...
Page 15
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Specular Excluded (SCE) • Illuminates when a specular excluded measurement is selected. Total (T) –...
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Sample Shelf A sample shelf is provided to help align a sample with the measurement port. It is also useful for providing consistent sample placement when multiple samples require a measurement at the same location.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Sample Door The sample door can be opened for a completely unobstructed view of the sample presented at the view port.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R either setting (or both if you have dual mode) on the front panel becomes illuminated based on your selection.
Page 19
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 3. Locate the plate to be installed in the accessory drawer and fit the aperture over the rim on the sample door.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R CALIBRATING The spectrophotometer should be calibrated every eight hours of operation. Each spectrophotometer configuration that is used should be calibrated.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 6. Remove the black trap from the accessory drawer and position it on the aperture plate. Make sure to align the tab at the top edge of the trap with the notch at the top of the aperture plate.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Transmission Calibration Procedure (excludes Ci7500 series) To calibrate your spectrophotometer in transmission measurement mode, you need to first locate the following items in your optional transmission kit: Aperture plates 6 mm, 10 mm, 17 Transmission sample holder...
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 6. Refer to the remaining Total, Direct, or R/T Calibration procedures that follow. Total Calibration 1.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 5. Once the calibration process is complete, the calibration LED becomes lit. Any change to the spectrophotometer configuration may result in the calibration LED turning from green (calibrated) to red (not calibrated).
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 5. Once the calibration process is complete, the calibration LED becomes lit. Any change to the spectrophotometer configuration may result in the calibration LED turning from green (calibrated) to red (not calibrated).
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R UV Calibration Procedure Note: UV Calibration requires the configured reflectance aperture plate to be installed. 1.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R MEASURING You should refer to the documentation or online help for the software application that you are using with your instrument.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Transmission Measurements (excludes Ci7500 series) A transmission indicator illuminates on the front panel based on your selection in the software. The transmission sample holder is designed to mount inside the transmission compartment.
Page 29
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 3. Open the transmission cover by lifting up on the locking pin while sliding the cover to the back.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 6. Pull the clamp back and position the sample between the clamp and stop. You may want to temporarily tighten the carriage base thumb screw to hold the clamp in place while positioning the sample.
Page 31
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 4. Align the sample holder base plate pins to the base plate mounting channel holes inside the transmission area.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Transmission holder with sample at the lens (direct measurement) for 25 mm measurements 7.
Page 33
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 6. When taking the transmission measurement the sample is held in position using the transmission holder with a stop plate on the sphere side of the sample, and a spring loaded clamping plate on the side of the sample away from the sphere.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R R/T correlation - Ci7XX0 to Ci7000A Testing has shown that to achieve the best correlation between a Ci7XX0 to a Ci7000A the following combinations of transmission port, stops, and aperture plates should be used: •...
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Cuvette in the cell stand (total measurement) 5. Initiate the measurement by selecting “Measure Standard" or "Measure Trial" from your software application, or press the Standard or Trial button on the front panel.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Cleaning the Instrument Your instrument requires very little maintenance to achieve years of reliable operation. However, to protect your investment and maintain reading accuracy, a few simple-cleaning procedures should be performed from time to time.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R General Exterior Cleaning The case, front panel, sample holder and surface of your instrument should be kept clean and free of dust.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 3. Close the sample door. Cleaning the Aperture Plates The surface of the aperture plate may be wiped clean with a cloth dampened in water or a mild cleaner.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 4. Blow short bursts of clean, dry air (4) across the both surface of the trap glass and inside of the trap.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Replacing the Fuse In the event the instrument does not turn ON when power is applied, make certain that power is available at the plug.
Calibration procedure Calibration tile is dirty or damaged. fails. Clean the white tile per procedure in Appendix, or replace if damaged. If damaged, arrange for replacement by contacting X-Rite Support. Instrument and Interface cable not connected. software not Connect the interface cable between the computer and the instrument.
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Specifications Performance Specifications Ci7860 Series Ci7800 Series Ci7600 Series Ci7500 Series Repeatability 0.01 RMS ∆E CIELAB...
Page 44
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Environmental Specifications Electrical Requirements 100-240 VAC/50-60 Hz AC line input is 1.1 Amps max Class 1, protective earth Overvoltage Category Category II...
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R Spare Parts and Accessories The Ci7XX0 Spectrophotometer has optional accessories that you may order by calling the Customer Service Department in the US at 1-800-248-9748.
System Repacking Instructions Refer to the following instructions to repack your system in the event shipment is required. If the original carton and packing materials are not available, contact X-Rite to have a replacement shipped to your location. Items to repackage with original shipped instrument: •...
Page 47
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R d. Package sample shelf (if installed on your instrument). i.
Page 48
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R h. Insert the white shipping wedges under the edges of the instrument cover as shown below (if available from original packaging).
Page 49
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R vi. Close the accessory drawer. UV tile Green tile White tile 3.
Page 50
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 4. Insert Instrument into box a. Lower instrument into box. i.
Page 51
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 5. Install contents into foam tray compartments as shown and place tray into the box. Aperture kit Cleaning kit Place these items in...
Page 52
C i 7 X X 0 B E N C H T O P S P E C T R O P H O T O M E T E R 6. Place top cardboard protective sheet on top of foam tray (if available from original packaging).
Page 54
Switzerland Phone (+41) 44 842 24 00 Fax (+41) 44 842 22 22 Asia Pacific Headquarters X-Rite Asia Pacific Limited Suite 2801, 28th Floor, AXA Tower Landmark East, 100 How Ming Street Kwun Tong, Kowloon, Hong Kong Phone (852) 2568 6283 Fax (852) 2885 8610 Please visit www.xrite.com for a local office near you.
Need help?
Do you have a question about the Ci7860 Series and is the answer not in the manual?