Attaching The Connecting Rod - JUKI LZ-2290CS Instruction Manual

Hide thumbs Also See for LZ-2290CS:
Table of Contents

Advertisement

2-15. Attaching the connecting rod

WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the
following work after turning the power off and a lapse of 5 minutes or more.
B
A
1) Fix connecting rod ❶ to installing hole B of ped-
al lever ❷ with nut ❸ .
2) Installing connecting rod ❶ to installing hole A
will lengthen the pedal depressing stroke, and
the pedal operation at a medium speed will be
easier.
3) The pressure increases as you turn reverse de-
pressing regulator screw ❹ in, and decreases as
you turn the screw out.
1. If the screw is excessively loosened,
the spring will come off. Loosen the
screw to such an extent that the top of
the screw can be observed from the
case.
2. Whenever you have adjusted the
screw, be sure to secure the screw by
tightening metal nut ❺ to prevent the
screw from loosening.
– 12 –