Introduction

1 Introduction

1.1 Purpose of the Design Guide

This design guide for Danfoss VLT
and FCM 106 is intended for:
Project and systems engineers.
Design consultants.
Application and product specialists.
The design guide provides technical information to
understand the capabilities of the frequency converter for
integration into motor control and monitoring systems.
The purpose of the design guide is to provide design
considerations and planning data for integration of the
frequency converter into a system. The design guide caters
for selection of frequency converters and options for a
diversity of applications and installations.
Reviewing the detailed product information in the design
stage enables developing a well-conceived system with
optimal functionality and efficiency.
®
VLT
is a registered trademark.

1.2 Additional Resources

Available literature:
®
VLT
DriveMotor FCP 106/FCM 106 Operating
Instructions, for information required to install and
commission the frequency converter.
®
VLT
DriveMotor FCP 106/FCM 106 Design Guide
provides information required for integration of
the frequency converter into a diversity of
applications.
®
VLT
DriveMotor FCP 106/FCM 106 Programming
Guide, for how to program the unit, including
complete parameter descriptions.
®
VLT
LCP Instruction, for operation of the local
control panel (LCP).
®
VLT
LOP Instruction, for operation of the local
operation pad (LOP).
Modbus RTU Operating Instructions and VLT
DriveMotor FCP 106/FCM 106 BACnet Operating
Instructions for information required for
controlling, monitoring, and programming of the
frequency converter.
MG03M202
Design Guide
®
DriveMotor FCP 106
®
Danfoss A/S © 06/2016 All rights reserved.
®
The VLT
PROFIBUS DP MCA 101 Installation Guide
provides information about installing the
PROFIBUS and troubleshooting.
®
The VLT
PROFIBUS DP MCA 101 Programming
Guide provides information about configuring the
system, controlling the frequency converter,
accessing the frequency converter, programming,
and troubleshooting. It also contains some typical
application examples.
®
VLT
Motion Control Tool MCT 10 enables configu-
ration of the frequency converter from a
Windows
-based PC environment.
®
Danfoss VLT
Energy Box software, for energy
calculation in HVAC applications.
Technical literature and approvals are available online at
vlt-drives.danfoss.com/Support/Service/.
®
Danfoss VLT
Energy Box software is available at
www.danfoss.com/BusinessAreas/DrivesSolutions, PC software
download area.
1.3 Symbols, Abbreviations, and
Conventions
The following symbols are used in this manual.
NOTICE
Indicates important information to be regarded with
attention to avoid mistakes or to avoid operating
equipment at less than optimal performance.
* Indicates default setting.
Degree of
The degree of protection is a standardised
protection
specification for electrical equipment that
describes the protection against the ingress of
foreign objects and water (for example: IP20).
DIx
DI1: Digital input 1.
DI2: Digital input 2.
EMC
Electromagnetic compatibility.
Error
Discrepancy between a computed, observed, or
measured value or condition, and the specified
or theoretically correct value or condition.
Factory
Factory settings when the product is shipped.
setting
Fault
An error can cause a fault state.
Fault reset
A function used to restore the frequency
converter to an operational state after a detected
error is cleared by removing the cause of the
error. The error is then no longer active.
MM
Memory module.
1
1
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt drivemotor fcm 106

Table of Contents