Specifications
6.1.2 Motor Frame Size Corresponding to
FCP 106 Enclosure
PM motor
1500 3000
71
–
71
71
71
71
71
71
90
71
90
90
90
90
112
90
6
6
112
112
Table 6.3 Motor Frame Size Corresponding to FCP 106 Enclosure
6.1.3 FCP 106 Dimensions
Illustration 6.2 FCP 106 Dimensions
Enclosure
type
MH1
MH2
MH3
Table 6.4 FCP 106 Dimensions
1) Power ratings relate to NO, see chapter 6.2 Electrical Data.
60
VLT
Asynchronous motor
RPM
Enclosure
3000
1500
–
–
71
80
MH1
80
90
80
90
90
100
90
100
MH2
100
112
112
112
MH3
112
132
X
Length
Power
1)
[mm (in)]
[kW (hp)]
3x380–480 V
A
0.55–1.5 (0.75–2.0) 231.4 (9.1) 130 (5.1) 162.1 (6.4) 106.8 (4.2)
2.2–4.0 (3.0–5.0)
276.8 (10.9) 166 (6.5) 187.1 (7.4) 113.2 (4.5)
5.5–7.5 (7.5–10)
321.7 (12.7) 211 (8.3) 221.1 (8.7) 123.4 (4.9)
Danfoss A/S © 06/2016 All rights reserved.
®
DriveMotor FCP 106/FCM 106
FCP 106
Power
[kW (hp)]
0.55 (0.75)
0.75 (1.0)
1.1 (1.5)
1.5 (2.0)
2.2 (3.0)
3 (4.0)
4 (5.0)
5.5 (7.5)
7.5 (10)
Y
Width
[mm (in)]
Normal lid
a
B
C
Height
Cable gland
[mm (in)]
diameter
High lid for
®
VLT
PROFIBUS DP
MCA 101
option
C
X
121.4 (4.8)
M20
127.8 (5.0)
M20
138.1 (5.4)
M20
Mounting
hole
Y
M20
M6
M20
M6
M25
M6
MG03M202
Need help?
Do you have a question about the VLT DriveMotor FCP 106 and is the answer not in the manual?
Questions and answers