POWER CONNECTIONS

Set aside an electrical circuit that is used exclusively for tools. It should be at least a #12 wire
and protected with a 15 AMP time lag fuse. Before connecting the motor to the power source,
make sure that the voltage is the same as indicated on the machine, and that the machine is
turned off. Check all connections for good contact. WARNING: If the machine runs on
insufficient voltage, damage to the motor may occur.
GROUNDING
Failure to adequately ground the machine may result in electric shock to the operator. Always
use a three prong extension cord and outlet. If there is any doubt that the outlet is not grounded
properly, have it checked by a certified electrician. Only use three to two adapters temporarily.