EXTENSION CORDS

Check the condition of the extension cord regularly. Use a three wire extension cord with a
three prong plug, and make sure it is plugged into an appropriate three hole receptacle. If you
must use a two prong adapter temporarily, make sure the grounding extension on the adapter
is connected to a permanent ground. Do not bend the grounding plug to fit it into a two hole
receptacle. Remember to use a cord heavy enough to carry the jointer's current. If the cord
length is under 25 feet for 110V operation, and under 50 feet for 220V operation, use at least
a 14 AWG gauge extension cord. If the cord length is between 25 and 50 feet for 110V
operation, and between 50 and 100 feet for 220V, use at least a 12 AWG gauge extension cord.
Do not use cords longer than 50 feet and 100 feet for 110V and 220V operations respectively.

CHANGING VOLTAGE

This machine is set up at the factory for 110V
use. To change the voltage to 220V, disconnect
the machine from its power source and follow
the electrical diagram as shown below.

SWITCH WIRING DIAGRAM