ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY!ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE DRILL PRESS DISCONNECTED FROM THE POWER
SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
POWER SUPPLY
WARNING: YOUR DRILL PRESS MUST BE CONNECTED TO
!
A 110V, 15-AMP, BRANCH CIRCUIT AND USE A 15-AMP TIME
DELAY FUSE OR CIRCUIT BREAKER. FAILURE TO CONNECT IN
THIS WAY CAN RESULT IN INJURY FROM SHOCK OR FIRE.
Your drill press must be properly grounded. Not all outlets are
properly grounded. If you are not sure if your outlet is properly
grounded, have it checked by a qualified electrician.
WARNING: IF NOT PROPERLY GROUNDED, THIS DRILL
!
PRESS CAN CAUSE ELECTRICAL SHOCK, PARTICULARLY
WHEN USED IN DAMP LOCATIONS. TO AVOID SHOCK OR FIRE,
IF THE POWER CORD IS WORN OR DAMAGED IN ANY WAY,
HAVE IT REPLACED IMMEDIATELY.
GROUNDING
This drill press must be grounded. If it should malfunction or
breakdown, grounding provides a path of least resistance for electric
current, to reduce the risk of electric shock. This drill press is
equipped with a cord having an equipment-grounding conductor
and grounding plug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in accordance with all
local codes and ordinances.
WARNING: TO MAINTAIN PROPER GROUNDING OF YOUR
!
DRILL PRESS, DO NOT REMOVE OR ALTER THE GROUNDING
PRONG IN ANY MANNER.
110V OPERATION
As received from the factory, your drill press is ready to run for 110V
operation. This drill press is intended for use on a circuit that has an
outlet and a plug which looks like the one illustrated in Fig.3.
WARNING: DO NOT USE A TWO-PRONG ADAPTOR FOR
!
THEY ARE NOT IN ACCORDANCE WITH LOCAL CODES AND
ORDINANCES. NEVER USE IN CANADA.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the
following table to determine the minimum wire size (A.W.G.-American
Wire Gauge) extension cord. Use only 3-wire extension cords which
have 3-prong grounding type plugs and 3-hole receptacles which
accept the tool's plug.
For circuits that are further away from the electrical circuit box, the wire
size must be increased proportionately in order to deliver ample
voltage to the dust collector motor. Refer to Fig. 4 for wire length and
size.

ELECTRICAL CONNECTIONS

WARNING
!
PROPERLY GROUNDED OUTLET
CURRENT CARRYING
PRONGS
GROUNDING
PRONG
FIGURE 3
LENGTH OF
CONDUCTOR
0-25 FEET
26-50 FEET
51-100 FEET
FIGURE 4
110V WIRING DIAGRAM
BLACK
MOTOR
MOTOR CORD
WHITE
GREEN
WHITE
WHITE
LIGHT
WHITE
POWER CORD
FIGURE 5
WIRE SIZES REQUIRED
(AMERICAN WIRE GAUGE)
110V LINES
NO.16
NO.14
NO.12
GREEN
BLACK
POWER
SWITCH
WIRE
CONNECT
BLACK JUMPER
LIGHT
BLACK
SWITCH
BLACK
GREEN