Linde 350 Series Service Training page 81

Ic engined truck with linde hydraulic control lhc
Table of Contents

Advertisement

Service Training
5K11 Flashing light during reversing
5K11:0
Flashing light off
5K11:0/1
Flashing light on alternately
5K12 Reversing light
5K12:0
Light off
5K12:1
Light on
NOTE:
Optional equipment can be connected via outputs 5K10, 11, and 12.
WINDOW 51
(MASTER VERSION) ADDITIONAL INFORMATION ON OUTPUTS
The switching states are indicated by the digits 0 and 1:
0: output off
1: output on
1K1 Safety relay
1Y4 Release valve
5K*s Status of lamp power stage
to *
For the outputs 5K10, 5K11, 5K12, 1H20 there is only one status signal which indicates the 4 outputs
mentioned above jointly. Depending upon the type of equipment on the truck, a different number of
outputs are used. The meaning of 5K*s is therefore that the status of 1 or 2 or 3 or 4 outputs is indicated
simultaneously.
X Y Z
X Y Z
Power stage feedback to safety processor
Control signal from safety processor
Control signal from master processor
Section