Linde 350 Series Service Training page 143

Ic engined truck with linde hydraulic control lhc
Table of Contents

Advertisement

Service Training
47
Current of release valve is too low
Release valve 1Y4 can not be activated --> window 5
Possible causes: inherent resistance of solenoid of valve 1Y4 is too large or solenoid not
connected; cable loom
Truck responses: W – B
51
Current of solenoid for IC engine is too high
The vehicle detects too high a current value for solenoid iY1 to speed controller, over 1.8 A --
> window 6
Possible causes: short in solenoid iY1 or in cable loom to solenoid iY1
Truck responses: W – E – L – F – S
52
Current of solenoid for IC engine is too low
The vehicle detects too low a current value for solenoid iY1 to speed controller --> window 6
Possible causes: cable loom has an open connection to solenoid iY1, solenoid defective.
Truck responses: W – E – L – F – S
53
Current for pump forward solenoid is too high
Current value for proportional solenoid iY2 is too high. --> window 6
Causes: short in proportional solenoid iY2 or in cable loom to the solenoid
Truck responses: W – E – L – F – S
54
Current for pump forwards solenoid is too low
The vehicle detects too low a current value for proportional solenoid iY2
--> Window 6
Possible causes: cable loom has an open connection to solenoid iY2, proportional solenoid
defective
Truck responses: W – E – L – F – S
55
Current for pump reverse solenoid is too high
The current value for proportional solenoid iY3 is high --> window 6
Possible causes: short in proportional solenoid iY3 or in cable loom to the solenoid.
Truck responses: W – E – L – F –S
56
Current for pump reverse solenoid is too low
The vehicle detects too low a current value for proportional solenoid iY3
--> window 6
Possible causes: cable loom has an open connection to solenoid iY3, proportional solenoid
defective
Truck responses: W – E – L – F – S
57
Current for gas shutoff valve is too high
The current applied to gas shutoff valve solenoid 1Y5 is too high
Possible causes: short in/at gas shutoff valve solenoid 1Y5 or in the cable loom to the solenoid.
Truck response: W
Section
02.01
Page
2
117

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H 12 d-03H 18 d-03H 16 d-03H 20 d-03H 18 t-03H 20 t-03

Table of Contents