WINDOW 31
STORED ERRORS
In window 31 (press key 3 and 1) the faults remain stored. The controller will set a slash at the end of the
fault codes and all malfunctions occurring thereafter will be shown again behind the slash.
Fault number
Fault frequency
If a memory overflow occurs, the earliest stored faults will be deleted. The maximum number of faults that
can be indicated is 9. If the frequency indicated is 9 this means that the fault can have occurred over 9 times.
A repetitive fault is incremented each time the ignition switch is turned on.
In the example fault 32 was detected two times. Then the service engineer acknowledged the fault. The
fault occurred again twice subsequently.
The fault codes have the following meaning:
Fault messages:
The following reactions can occur on the truck with individual faults:
W
Warning lamp flashing
K
Truck driving at creep speed
B
Truck brakes to a full stop or remains stationary when not moving
R
Current achieves only start of pump control
E
All power stages are without power
L
engine goes to low idling speed
F
Release magnet de-energised, truck braking with brake jets (restrictors)
S
Safety relay in the controller de-energised, all power stages without power
Test conditions:
Battery min. 11.3 V
Potentiometer calibration --> window 8
NOTE:
If no calibration is possible, there may be a problem with the pedal mechanism in addition to
a defective potentiometer.
02.01
Sign showing fault was acknowledged by service engineer
Fault number and frequency of occurrence after acknowledgement