Service Training
- Connect the voltmeter between terminal 1(-) and terminal 15 (+) of the ignition coil.
- Switch on the ignition.
Desired value: min. 2 V, must drop to 0 V after 1 to 2 seconds. If not, replace the TSZ switch unit and test
the ignition coil for emerging sealing compound; replace it as well, if required.
- Touch the centre pin of the distributor connector to earth. The voltage should briefly read at least 2 V. If
not, locate the break in the centre cable and remedy the fault, or replace the TSZ switch unit.
- Switch off the ignition.
- Connect the voltmeter to the outside pins on the Hall generator (distributor).
- Switch on the ignition
Desired value: min. 5 V
NOTE:
If the malfunction persists despite obtaining the desired values, replace the TSZ switch unit, or
locate and remedy a break in the cable between the Hall generator plug and the switch unit.