Linde 350 Series Service Training page 63

Ic engined truck with linde hydraulic control lhc
Table of Contents

Advertisement

Service Training
INTERFACE CONVERTER STATUS
This symbol, two connectors, appears to the right of the serial interface symbol at the bottom of the computer
window. When the interface converter is correctly installed and correctly operating, the two plugs are together
and green in colour. If the two connectors are open and red in colour, a problem exists with the data transfer
(false COM serial interface, the interface converter is incorrectly installed or the key switch is not turned on).
ACCESS TO PROGRAM
Key symbol
Open lock symbol
The diagnostic program works with menu windows. Each window shows different information about the truck.
The windows are called up by simply entering the window number, e.g. 1. When calling up a window with
two digits e.g. 72, simply quickly enter the two digits in the correct order. If you wish to change to another
window, enter the new window number. Depending on the software version for the controller, the following
windows can be displayed.
Window 1:
M
Window 11:
M
Window 12:
Window 2:
Window 3:
Window 31:
Window 32:
M
Window 33:
Window 4:
M
Window 41:
Window 5:
M
Window 51:
Window 6:
M
Window 61:
M
Window 62:
Window 7:
Window 71:
M
Window 72:
M
Window 73:
M
Window 74:
M
Window 75:
M
Window 76:
Window 8:
Service program
Master program (menu windows M can be displayed)
Information on software version and truck type
Information on truck type code in the cable loom
Comparison of master and safety processor codes
Current fault messages
Stored fault messages
Clearing fault messages in window 3 (up to including version 1.3)
Stored fault messages (up to including version 1.3)
Clearing window 32 (up to including version 1.3)
Inputs
Switch signals of both processors
Outputs
Additional information on outputs
Analogue values
Analogue values (master and safety processor) - potentiometer
Analogue values (master and safety processor) - potentiometer and pump
control solenoids.
Setting truck speed and specified RPM
Resetting parameters to standard factory settings
Seat switch
Resetting parameters of window 72 to standard factory settings
Maximum speed
Setting of initial inverse current and final pump current
Resetting parameters of window 75 to standard factory settings
Zero adjustment of potentiometer (teach-in)
Section
02.01
Page
2
37