Service Training
1S2 Lift pressure
1S3 Aux. hydraulics 0: not operated or not connected
WINDOW 41
(MASTER VERSION) SWITCH SIGNALS OF BOTH PROCESSORS
The switching states are indicated by the digits 0 and 1:
0: contact open
1: contact closed
The signals are displayed in pairs (XY) with following declaration:
X is the switch signal read by the master processor
Y is the signal of the same switch read by the safety processor
During faultless operation X always equals Y, with both processors seeing the same status of a switch.
1S8 Seat switch
XY
00
11
00
1S25 Travel direction XY
0: < 14 bar
1: > 14 bar
1: operated
XY
11
not operated
00
operated
00
possibly not present
XY
XY
00
00 / 11: 1-pedal at zero position
11
00 / 11: 1-pedal forward
00
11 / 11: 1-pedal reverse
11
11 / 00: 2-pedal
Section
02.01
Page
2
121