WINDOW 61
(MASTER VERSION) ADDITIONAL INFORMATION 1 TO ANALOGUE READINGS
The analogue readings shown here have the following meaning:
vs:
Potentiometer supply voltage ± 200 mV
v1:
Potentiometer voltage 1B2.1 in mV (physical)
p1:
Potentiometer actual voltage in % (-100 (reverse) up to + 100 (forwards))
v1 + v2:
Potentiometer voltage 1B2.1 and 1B2
(desired value 9 - 11 V) with a supply of 10 V
v2:
Potentiometer voltage 1B2.2 in mV (physical)
v3:
voltage for working hydraulics pressure sensor (1000 - 9000 mV)
WINDOW 62
(MASTER VERSION) ADDITIONAL INFORMATION 2 TO ANALOGUE READINGS
The analogue readings shown here have the following meaning:
vs:
Potentiometer supply voltage ± 200 mV
v1:
Potentiometer voltage 1B2.1 in mV (physical)
Potentiometer voltage 1B2.1 in mV (at processor)
iY2:
Desired current for pump valve forwards
Desired current for pump valve forwards (at processor)
iY3:
Desired current for pump valve reverse
Desired current for pump valve reverse (at processor)