Genie GTH-3512 Operator's Manual page 111

Table of Contents

Advertisement

PROBLEM
ALARM MESSAGES OF THE DLE
MOMENT LIMITING SYSTEM
SHOWN ON THE DISPLAY
ATTENTION
In case of faults not listed in this chapter, address to the GENIE Technical Service, your nearest authorised
workshop or dealer.
Handler with telescopic boom GTH-3512
PROBLEMS AND TROUBLESHOOTING
CAUSES
4 Block relay error during operation
5-6-7-8 Block relay error when power
is turned on
9 CELL 1 and CELL 2 reading
incongruence. The values read from
the two cells are different.
A Data error in RAM
B Outrigger incongruence
C Error during check of A.D.C. reading
E - 5
Page
Document 57.0008.7200 - 05/2007
SOLUTIONS
• Check the efficiency of relay and
wiring
• Stop and restart the machine and
run a complete test to check the
outputs.If the error message is still
shown, contact the GENIE service
centre to replace the DLE unit.
• Check the efficiency of relay and
wiring
• Stop and restart the machine and
run a new test. If the error message
is still shown, contact the GENIE
service centre to replace the DLE
unit.
• Check that the cells are intact and
fixed correctly. If the error message
is still shown, contact the GENIE
service centre to replace the load
cell and re-calibrate the unit.
• Stop and restart the machine. If the
error message is still shown, contact
the GENIE service centre.
• An input is not read. Check the
wiring, the power cord and the
connector of the DLE. If the alarm
persists, contact the GENIE service
centre.
• Stop and restart the machine. If the
error message is still shown, contact
the GENIE service centre.
Courtesy of Crane.Market

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents