D-3.9.2 Auxiliary circuits oil filter
■
To change the hydraulic oil filter cartridge of the service
circuits, proceed as follows:
1
Stop the machine on a level ground and engage the
parking brake.
2
Remove the inspection hatch
oil filter fitted inside the tank.
3
Check the tank is clean, then fit a new filtering
element and refit the inspection hatch.
4
Check the oil level within the tank. Add new oil, if
necessary.
SERVICE INTERVAL
Running-in ____________________________ None
Ordinary __________________ Every
Handler with telescopic boom GTH-3512
MAINTENANCE
D-3.10 OIL LEVEL IN THE DIFFERENTIAL GEARS
■
To check the oil level in the front and rear differential
gears:
•
Stop the machine on a level ground and engage the
parking brake.
•
Loosen level plug
and unscrew the
hole.
•
If necessary, top-up through hole
out from hole
•
Refit and tighten plugs
To change the oil:
•
Place a container of suitable size under drain plug
•
Loosen the drain plug, the level plug
•
Refit and tighten drain plug
•
Add new oil through the filler until it is level with hole
•
Refit and tighten plugs
500
hours
Running-in _________ Within the first
Ordinary __________________ Every
D - 14
Page
Document 57.0008.7200 - 05/2007
and check if oil is level with the
.
and
.
and allow oil to flow out from the reduction gear.
.
and
SERVICE INTERVAL
until oil comes
.
and the filler
.
.
10
hours
250
hours
Courtesy of Crane.Market