Registration And By-Pass Unit Removal - Ricoh B064 Service Manual

Hide thumbs Also See for B064:
Table of Contents

Advertisement

PAPER FEED

3.11.15 REGISTRATION AND BY-PASS UNIT REMOVAL

[B]
1. Remove the development unit. (☛ 3.6.1)
2. Remove the inner cover. (! x4)
3. Disconnect the toner bottle holder connector [A] and counter connector [B].
4. Pull out the duplex unit about 10 cm.
• Confirm that the registration roller is separated from the positioning pin.
5. Remove the right upper cover. (☛ 3.3.3)
6. Rear upper cover (☛ 3.3.5)
7. Disconnect the following connectors:
• Relay clutch connector [C]
• Guide plate solenoid connector [D]
• Guide plate sensor connector [E]
• By-pass tray unit connectors [F]
B064/B065
[A]
[C]
3-102
[D]
[E]
[F]
B064R712.WMF
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B065

Table of Contents