Ipu Printing Test Pattern: Sp2902 004 - Ricoh B064 Service Manual

Hide thumbs Also See for B064:
Table of Contents

Advertisement

Rev. 10/2002

5.3.3 IPU PRINTING TEST PATTERN: SP2902 004

This test pattern is generated in the application input processing circuit in the IPU.
The operation path is as follows:
This test pattern is primarily used for design purposes, but it can also be used to
trace the source of problems beyond the IPU (in the application input or BICU)
which are causing poor print quality.
1. Enter the SP mode and select SP2902 004.
2. Enter the number for the test pattern that you want to print and press . (See
the table below.)
No.
0
None
1
Vertical Cross Stitch (4 beam)
2
Horizontal Cross Stitch (4 beam)
3
Grayscale OPC
4
Horizontal Grayscale 20
5
Horizontal Grayscale 20 – 17lpi
3. When you are prompted to confirm your selection, press Yes to select the test
pattern for printing.
4. Press Copy Window to open the copy window, then select the settings for the
test print (paper size, etc.)
5. Press Start  twice (ignore the "Place Original" messages) to start the test
print.
6. Press SP Mode (highlighted) to return to the SP mode display.
7. Switch the machine off and on.
SM
Application input " Memory " Printer
Pattern
5-9
TEST PATTERN PRINTING
B064/B065

Advertisement

Table of Contents
loading

This manual is also suitable for:

B065

Table of Contents