11) Parameter group 400: Analogue I/O channel configuration

Non-linear characteristic for analogue channels

A non-linear characteristic can be assigned to analogue input channels
sense of the table below
F460
Characteristic
AI1
F461
Characteristic
AI2
F462
input level 1 for
AI1
F463
Assignation input level 1 (%)
F464
input level 2 for
AI1
F465
Assignation input level 2 (%)
F466
input level 3 for
AI1
F467
Assignation input level 3 (%)
F468
input level 1 for
AI2
F469
Assignation input level 1 (%)
F470
input level 2 for
AI2
F471
Assignation input level 2 (%)
F472
input level 3 for
AI2
F473
Assignation input level 3 (%)
Assignation of intermediate pints, in the same way as for endpoints
(0= -100%, 1=0%, 2=+100%)
E800 – Rev.01 -EN- SOFT Rev. 2.04
© 2015 EURADRIVES EUROPE GmbH
Selection: 0=linear
1=non-linear
Selection: 0=linear
1=non-linear
Range: F400 - F464
Range: F401 - F465
Range: F462 - F466
Range: F463 - F467
Range: F464 - F402
Range: F465 - F403
Range: F406 - F470
Range: F407 - F471
Range: F468 - F472
Range: F469 - F473
Range: F470 - F412
Range: F471 - F413
- 49 -
AI1
and AI2. Programming is done in
Default setting: 0
Default setting: 0
Default setting: 2.00V
Default setting: 1.20
Default setting: 5.00V
Default setting: 1.50
Default setting: 8.00V
Default setting: 1.80
Default setting: 2.00V
Default setting: 1.20
Default setting: 5.00V
Default setting: 1.50
Default setting: 8.00V
Default setting: 1.80
100
F400
A1 A2
A3
F402