Control-Board: Hardware And I/O Channel Configuration; Digital Input Channels - EURA DRIVES E800 series Safety Instructions, Installation And Operating Manual

0,2kw – 110kw (ip20)
Table of Contents

Advertisement

5) Steuerhardware und Hardware-Konfiguration der I/O Steuerkanäle

5) Control-board: hardware and I/O channel configuration

I/O channel configuration is a combination of hardware and software setting
For software parameter setting see chapter:
10) Parameter group 300: Configuration of digital I/O channels
11) Parameter group 400: Configuration of analogue I/O channels
Two different type of control boards are used in E800 inverter concept:
Control board for inverter 0,2 - 22 kW: Framesize E1 - E6
Control board for inverter 30kW - 90 kW: Framesize C3 – C6
Control board
0,2...22kW
SZ E1 - E6:
E1 - E6:

Digital input channels:

A total of 5 digital input channels DI1.....DI5 are available on inverter, size
E1-E6.
Different functions can be assigned to
these inputs, programming the parameter F316....F320 – description: see chapter 10) Parameter group 300: Configuration of
digital I/O channels
Attention:
A function can be assigned to one single digital input only (no multiple inputs for same function allowed) If a
function is already assigned to a certain input (due to factory set), this assignment must be deleted (set function-code
to 0), before assigning to another input.
HIGH/LOW active (PNP/NPN) control-mode selection: This selection is done via hardware setting of the NPN-PNP DIP-
SWITCH on the control board.
All digital inputs are isolated from analogue ground, the 24 V (50mA) auxiliary power supply may be used for input control in
PNP mode. CM is the common reference point for all digital inputs.
E800 – Rev.01 -D- SOFT Rev. 2.04
- 23 -
© 2015 EURADRIVES EUROPE GmbH