Transmission Ratio; Pulley Diameter - EURA DRIVES E800 series Safety Instructions, Installation And Operating Manual

0,2kw – 110kw (ip20)
Table of Contents

Advertisement

F132
Display: Selection of operating
parameters to display during „STOP"
status (Motor stopped)
With inverter in STOP mode, the display will always show the target frequency - flashing
Following table shows the units and display-mode for various parameters:
Motorspeed (rpm):
Motor Current
A (A.A)
Motor-Voltage:
Counter status:
DC-Voltage:
u (VVV)
Heatsink temperature:
Calculated speed L(sss). Decimal point to indicate values above 999, two decimal points for values above 9999
PID controller Set-Point (normalized):
PID Feed-Back (normalized):
Single phase inverter size E1 (0.2 - 0.75KW) do not have temperature indication.
Parameter, for calculated speed indication (display)
F133

Transmission ratio

F134

Pulley diameter

-Example: Max. Frequency F111=50.00Hz, number of poles F804=4, transmission ration F133=1.00, pulley diameter R=0.05m
(F134=0,05), calculation result: pulley circumference: 2πr =2×3.14×0.05=0.314 (meter), shaft speed: 60×frequency / (number of
poles × transmission ratio) = 60×50/ (2×1.00) =1500rpm. For linear speed: speed (rpm) × pulley circumference =
1500×0.314=471(meter/second)
E800 – Rev.01 -EN- SOFT Rev. 2.04
© 2015 EURADRIVES EUROPE GmbH
8) Parameter group 100: Basic parameters
0:
Target frequency / Parameter (Fxxx)
1:
Jog modus via keypad - HF-0
2:
Target motor speed (rpm)
4:
DC-voltage
8:
PID control feed back
16:
Heatsink temperature
32:
Reserved
64:
PID Set point
128: Reserved
256: Reserved
512: Reserved
1024: Reserved
2048: Reserved
(NNNN)
integer value – the decimal point indicates values above 9999.
U (VVV)
(ZZZZ)
H (TTT)
(o*.*)
(b *.*)
Range: 0.10 - 200.0
0.001 – 1.000 (m)
- 35 -
Default setting:
0+2+4=6
Default setting: 1.00
Default setting: 0.001