Error code
Description
202.22
Cartridge Motor - Motor Underspeed Error. Motor
made it to closed loop steady state, but then
detected speed was below threshold
202.28
Exit sensor bounce issue.
202.32
The sheet is too long to be duplexed. The blow
through is enabled.
202.36
Long paper or shingled multi feed stopped before
sending to duplex.
202.43
During warm up flush, media that passed the input
sensor failed to reach the exit sensor.
202.45
During warm up flush, sheet detected too long
over exit sensor.
Sensor (fuser exit) jam service check
Action
Step 1
Check the input sensor area for jammed media fragments.
Is the paper path free of partially fed or jammed media?
Step 2
Check the fuser exit sensor cable JEXIT1 for proper connection to
the controller board.
Is it properly connected?
Step 3
Check the fuser exit sensor for damage.
Is it free of damage?
Step 4
Check the fuser gears and rollers for damage.
Are they free of damage?
Step 5
Does the error remain?
Action
Go to
page
Go to
page
Go to
Go to
Go to
page
Go to
page
Diagnostics and troubleshooting
105
"Sensor (fuser exit) jam service check" on
105.
"Sensor (fuser exit) jam service check" on
105.
"Duplex service check" on page
"Duplex service check" on page
"Sensor (fuser exit) jam service check" on
105.
"Sensor (fuser exit) jam service check" on
105.
Yes
No
Go to step 2.
Clear the paper path
of any media
fragments.
Go to step 3.
Reseat the cable.
Go to step 4.
Replace the fuser.
See
removal" on
page
Go to step 5.
Replace the fuser.
See
removal" on
page
Contact the next
The problem is
level of support.
solved.
7015
106.
106.
"Fuser
375.
"Fuser
375.