Omron NJ Series Troubleshooting Manual page 154

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
247A 0000 hex
Number of
Distributed
Sensor Unit
Verify Error
247B 0000 hex
Number of
Sensors Over
Limit
247C 0000 hex
Number of
Sensors Ver-
ify Error
247D 0000 hex
Number of
Sensors Over
at Distrib-
uted Sensor
Unit
34F8 0000 hex
Dummy Sen-
sors Setting
Error
04A1 0000 hex
Non-volatile
Memory
Hardware
Error
ZW-CE1@T Confocal Fiber Type Displacement Sensor
Event code
Event name
04D0 0000 hex
Hardware
error
14B00000 hex
Linearity cor-
rection data
error
14B10000 hex
Linearity cor-
rection data
read error
14B20000 hex
System set-
ting error
14B30000 hex
Bank data
error
3-92
Meaning
Assumed cause
The number of Dis-
• The Distributed Sensor Unit is
tributed Sensor Unit
disconnected
that is checked at
power up is
decreased.
Too many Sensors
• More than the maximum num-
are connected.
ber of Sensors are connected.
The number of Sen-
• The set value does not match
sors that is con-
the number of Sensors that are
nected does not
actually connected
agree with the set-
tings.
Too many Sensors
• More than the maximum num-
are connected at
ber of Sensors are connected
Distributed Sensor
at Distributed Sensor Unit.
Unit.
Too many Dummy
• There are too many Dummy
Units are set.
Units set, so some Sensors are
not assigned logical unit num-
bers.
An error occurred in
• Non-volatile memory failure
non-volatile mem-
ory.
Meaning
Assumed cause
Some abnormality
• Hardware damage
occurred on the dis-
placement sensor
hardware.
The linearity correc-
• Calibration ROM damage
tion data of the dis-
placement sensor
is damaged.
Reading of the dis-
• Calibration ROM not inserted
placement sensor
• Calibration ROM damage
linearity correction
data was not exe-
cuted correctly.
The system set-
• The displacement sensor
tings saved to the
power was turned OFF during
displacement sen-
saving/loading of system set-
sor are corrupt.
tings.
The bank data
• The displacement sensor
saved to the dis-
power was turned OFF during
placement sensor
saving/loading of bank data.
is corrupt.
Level
Maj
Prt
Min
Obs Info
S
EtherCAT Digi-
tal Sensor
Communica-
tions Unit
Operation
Manual (Cat.
No. E429)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
Level
Maj
Prt
Min
Obs Info
S
ZW-CE1@T
Confocal Fiber
Type Displace-
ment Sensor
User's Manual
(Cat. No.
Z332)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
NJ-series Troubleshooting Manual (W503)
Reference
Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj501-1500Nj501-1400Nj501-1300Nj301-1200Nj301-1100

Table of Contents