Omron NJ Series Troubleshooting Manual page 150

Machine automation controller sysmac
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
08030000 hex
Encoder
Communica-
tions Warn-
ing
08040000 hex
Encoder/Seri
al Conversion
Unit Over-
heating
Warning
08050000 hex
Life Expec-
tancy Warn-
ing
08060000 hex
External
Encoder
Error Warn-
ing
08070000 hex
External
Encoder
Communica-
tions Warn-
ing
34E00000 hex
Data Setting
Warning
383C 0000 hex
Overload
Warning
383D 0000 hex
Excessive
Regenera-
tion Warning
383E 0000 hex
Vibration
Detection
Warning
3-88
Meaning
Assumed cause
Encoder communi-
• There is insufficient power sup-
cations errors
ply voltage for the encoder.
occurred in series
• Noise is entering on the
more frequently
encoder line.
than the specified
value.
The encoder tem-
• The ambient temperature is too
perature exceeded
high.
the specified value
• Servomotor/Linear Motor failed.
or an overheating
warning was
detected for the
Serial Conversion
Unit.
The remaining life
• The life expectancy of the
of the capacitor or
capacitor or the fan is shorter
the fan is shorter
than the specified value.
than the specified
value.
The external
• There is insufficient power sup-
encoder detected a
ply voltage for the external
warning.
encoder.
• Noise is entering on the exter-
nal encoder connector cable.
• The external encoder failed.
The external
• There is insufficient power sup-
encoder had more
ply voltage for the external
communications
encoder.
errors than the
• Noise is entering on the exter-
specified value.
nal encoder connector cable.
An object setting is
• An object setting is out of
out of range.
range.
The load ratio is
• Overload
85% or more of the
• There is incorrect wiring of the
protection level.
motor line or a broken cable.
The regeneration
• There is excessive regenera-
load ratio is 85% or
tion.
more of the level.
• This Regeneration Resistor
cannot be used for continuous
regenerative braking.
Vibration was
• The gain or inertial ratio/mass
detected.
ratio setting is not suitable.
Level
Maj
Prt
Min
Obs Info
S
Cylinder-type
Motor Manual
(Cat. No. I576)
S
Cylinder-type
Motor Manual
(Cat. No. I576)
and Linear
Motor Manual
(Cat. No. I577)
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
S
Same as
above.
NJ-series Troubleshooting Manual (W503)
Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nj501-1500Nj501-1400Nj501-1300Nj301-1200Nj301-1100

Table of Contents