Measure Feature
Press plate size, then measure in Vision software. The machine goes into measure mode, the laser
pointer turns on, and the machine screen will change to the Measure screen shown below. Using the X
and Y jog buttons on this screen, jog the laser pointer to the top left corner of the desired engraving area
and press the green check (select) mark. Using the same X and Y jog keys, jog the laser pointer to the
bottom right corner of the desired engraving area and press the green (select) check mark. The software
automatically creates a plate size in this bounding area.
Emergency Stop Screen
When the Emergency button is activated on the machine the Emergency Stop Screen will appear on the
Front Panel and not allow the operator to do anything on the machine until the Emergency stop is
deactivated. Check to make sure whatever caused the Emergency Stop button to be activated has been
cleared or repaired and then twist the button until it "pops up" to clear the Emergency Stop.