Attribute
Maximum stacked switches
Maximum redundant fabrics per frame
1
Components:
Number of switches
Number of 20 G interconnect modules
Number of interconnect link cables
Number of QSFP+ stacking cables
Number of 20 G mezzanine cards
1
Double component counts for two redundant fabrics, and triple component counts for three redundant fabrics

Power cabling

The frame can be cabled for power feed redundancy or power supply redundancy.

Cabling power supplies for power feed redundancy

Power feed redundancy may be achieved by connecting 1+1, 2+2, or 3+3 power supplies to Phase A+B.
To cable a frame for power feed redundancy, use the following recommendation as a best practice:
1. Connect power supplies 1, 2, and 4 to the A-side power distribution unit.
2. Connect power supplies 3, 5, and 6 to the B-side power distribution unit.
3. Verify that the power supply cords are securely connected using the reusable cable tie wraps.
Value
8
3
2
4
8
2
36
Description
# of switches (interconnect
modules do not count towards
limit)
Redundant fabrics 1, 2, and 3
(A and B)
Cable lengths allow frames to
be in different racks
In this use case, QSFP+ ports
are used for stacking
Maximum for 36 compute
module (two or three frame)
deployment
Power cabling
67