Cabling
HPE Synergy Cabling Guide
For additional cabling scenarios and diagrams, see the HPE Synergy Cabling Guide (http://
www.hpe.com/info/synergy-cabling-guide).
The HPE Synergy Cabling Guide includes:
•
Multiframe cabling
•
HPE Image Streamer cabling
•
CAT6A patch panel LINK port cabling
•
Master to satellite Interconnect cabling
•
Power cabling
•
HPE Synergy Console cabling
Network cabling
To ensure the frame and installed components are connected to the network, the following connections
are required:
•
Single-frame management network cabling example on page 59
•
Master and satellite interconnect module cabling on page 60
Single-frame management network cabling example
This example shows cabling a single frame with two HPE Synergy Composers and two frame link
modules installed in the frame.
NOTE: For high availability, Hewlett Packard Enterprise recommends installing two HPE Synergy
Composers.
NOTE: Use a minimum of CAT6A patch cables for LINK port cabling.
NOTE: Do not connect frame link module LINK ports to a data center switch.
Procedure
1. Connect the MGMT ports on both frame link modules to the external management network.
2. Connect the LINK ports together.
Cabling