12.5 HygienicMaster - Material loads for process

connections

The limits for the permissible measuring medium temperature
(T
) and permissible pressure (P
medium
the basis of the lining and flange material used in the device
(refer to the name plate on the device).
Minimum permissible operating pressure
The following tables show the minimum permissible operating
pressure (P
) depending on measuring medium
medium
temperature (T
) and the liner material.
medium
Liner material
Nominal
diameter
PFA
DN 3 ... 100
(1/10 ... 4")
1) For CIP/SIP cleaning, higher temperatures are permitted for limited time
periods; refer to the chapter "Maximum permissible cleaning temperature" on
page 83.
Liner approvals on request; please contact ABB.
84 OI/FEP610/FEH610-EN Rev. B | ProcessMaster FEP610, HygienicMaster FEH610
) are calculated on
medium
P
T
1)
medium
medium
[mbar abs]
0
< 130 °C (266 °F)
Overview - Material load
Process
DN
connection
Wafer type
DN 3 ... 50
(1/10 ... 2")
DN 65 ... 100
(2 1/2 ... 4")
Welded spuds
DN 3 ... 40
DIN 2463,
(1/10 ... 1 1/2")
ISO 1127,
DN 50, DN 80
DIN 11850
(2", 3")
DN 65, DN 100
(2 1/2", 4")
Welded spuds
DN 25,
SMS 1145
DN 40 ... 100
(1",1,5 ... 4")
Threaded pipe
DN 3 ... 40
connection
(1/10 ... 1 1/2")
DIN 11851
DN 50, DN 80
(2", 3")
DN 65, DN 100
(2 1/2", 4")
Tri-Clamp
DN 3 ... 50
DIN 32676
(1/10 ... 2")
DN 65 ... 100
(2 1/2 ... 4")
Tri-Clamp
DN 3 ... 80
ASME BPE
(1/10 ... 3")
DN 100 (4")
External thread
DN 3 ... 25
ISO 228,
(1/10 ... 1")
DIN 2999
Welded spuds
DN 3 ... 50
OD tubing
(1/10 ... 2")
P
max.
T
medium
medium
40 bar (580 psi)
-25 ... 130 °C
(-13 ... 266 °F)
16 bar (232 psi)
40 bar (580 psi)
-25 ... 130 °C
(-13 ... 266 °F)
16 bar (232 psi)
10 bar (145 psi)
6 bar (87 psi)
-25 ... 130 °C
(-13 ... 266 °F)
40 bar (580 psi)
-25 ... 130 °C
(-13 ... 266 °F)
16 bar (232 psi)
10 bar (145 psi)
16 bar (232 psi)
-25 ... 130 °C
(-13 ... 266 °F)
10 bar (145 psi)
10 bar (145 psi)
-25 ... 121 °C
(-13 ... 250 °F)
8.6 bar
(124.7 psi)
16 bar (232 psi)
-25 ... 130 °C
(-13 ... 266 °F)
10 bar (145 psi)
-25 ... 130 °C
(-13 ... 266 °F)