FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | CI/FEP630/FEH630-EN REV. D
HygienicMaster – Material load for process connections
The limits of the permissible measuring medium temperature
(T
) and permissible pressure (P
medium
the basis of the liner and flange material used in the device (see
device name plate).
Minimum permissible operating pressure
The following tables show the permissible minimum operating
pressure (P
) as a function of the measuring medium
medium
temperature (T
) and the liner material.
medium
Lining material
PFA
DN 3 to DN 100
PEEK
*
For CIP/SIP cleaning, higher temperatures are permitted for limited time
periods; refer to Maximum permissible cleaning temperature on page 78.
Liner approvals on request; please contact ABB.
) are calculated on
medium
Nominal
P
medium
diameter
[mbar abs]
0 < 130 °C (266 °F)
(¹
to 4 in)
DN 1 to DN 2
0 < 120 °C (248 °F)
(¹
to ¹
in)
Overview – Material load
Process connection
Wafer type
Welded spuds
DIN 2463, ISO 1127,
DIN 11850
T
*
medium
Welded spuds
SMS 1145
Threaded pipe
connection
DIN 11851
Tri-Clamp
DIN 32676
Tri-Clamp
ASME BPE
External threads
ISO 228, DIN 2999
Welded spuds
OD tubing
in hygiene
connection
DN
P
max.
medium
DN 3 to 50
40 bar (580 psi)
(¹
to 2 in)
DN 65 to 100
16 bar (232 psi)
(2 ½ to 4 in)
DN 3 to 40
40 bar (580 psi)
(¹
to 1 ½ in)
DN 50, DN 80
16 bar (232 psi)
(2 in, 3 in)
DN 65, DN 100
10 bar (145 psi)
(2 ½ in, 4 in)
DN 25,
6 bar (87 psi)
DN 40 to 100
(1 in, 1.5 to 4 in)
DN 3 to 40
40 bar (580 psi)
(¹
to 1 ½ in)
DN 50, DN 80
16 bar (232 psi)
(2 in, 3 in)
DN 65, DN 100
10 bar (145 psi)
(2 ½ in, 4 in)
DN 3 to 50
16 bar (232 psi)
(¹
to 2 in)
DN 65 to 100
10 bar (145 psi)
(2 ½ to 4 in)
DN 3 to 80
10 bar (145 psi)
(¹
to 3 in)
DN 100 (4 in) 8.6 bar (124.7 psi)
DN 3 to 25
16 bar (232 psi)
(¹
to 1 in)
DN 3 to 50
10 bar (145 psi)
(¹
to 2 in)
DN 1 to DN 2
10 bar (145 psi)
(¹
to ¹
in)
79
T
medium
25 to 130 °C
( 13 to 266 °F)
25 to 130 °C
( 13 to 266 °F)
25 to 130 °C
( 13 to 266 °F)
25 to 130 °C
( 13 to 266 °F)
25 to 130 °C
( 13 to 266 °F)
25 to 121 °C
( 13 to 250 °F)
25 to 130 °C
( 13 to 266 °F)
25 to 130 °C
( 13 to 266 °F)
10 to 120 °C
( 14 to 248 °F)
Need help?
Do you have a question about the ProcessMaster FEP630 and is the answer not in the manual?