3.4
Viewing the POST Menus
To use the POST menus:
1. At the system prompt, type:
ok% setenv diag-switch? true
ok% setenv diag-level = menus
3.5
Initializing POST
POST can be initialized in two ways:
maximum POST reporting, or max
I
minimum POST reporting, or min
I
Note – The default POST setting is max.
To run POST you must:
Set diag-switch? to true.
I
Set the diag-level to either max or min.
I
Power-cycle the system.
I
To set the diag-switch? to true and power-cycle the system:
1. At the system prompt, type:
ok% setenv diag-switch? true
ok% setenv diag-level = min
Note – Type either min or max, depending on the functions you need to test.
2. Power-cycle the system by pressing and releasing the power switch on the front
panel.
3. Observe the terminal monitor to verify that POST is executing.
Chapter 3 Power-On Self-Test
3-5