Ratings Compatibility

Table 1: Communicator Ratings
Model
Power Supply Ratings
Input Voltage
Current Consumption
Standby Current
Alarm (Transmitting) Current
Operating Frequency
Typical Antenna Gain
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with bracket
Table 2: Compatible Receivers and Panels
Communicator
3G2080(R)
TL2803G(R)
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.

Encryption

The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the moni-
toring station receiver. Each receiver (Ethernet 1 and 2, cellular 1 and 2) can independently have
encryption enabled or disabled. When encryption is enabled, the central station will configure the
device to encrypt communications the next time the communicator module performs a communi-
cation to that receiver.
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the
unit is restarted.
Before leaving the installation site, the communicator TL2803G(R) Ethernet line shall be con-
nected via an APPROVED (acceptable to the local authorities) Network Interface Device (NID).
All wiring shall be performed according to the local electrical codes.
C
OMMUNICATOR
This Internet and HSPA(3G) dual-path alarm communicator shall be installed by service persons
only (service person is defined as a person having the appropriate technical training and experi-
ence necessary to be aware of hazards to which that person may be exposed to in performing a task
and can also take measures to minimize the risks to that person or other persons). The Communi-
cator shall be installed and used within an environment that provides the pollution degree max 2,
overvoltages category II, in non-hazardous, indoor locations only. This manual shall be used with
the installation manual of the panel which is connected to the communicator. All instructions spec-
ified within the panel manual must be observed.
HSPA(3G) Alarm Communicator Installation Manual
Power is supplied from the panel's PC-Link header or a PCL-422 module in
remote cabinet installations. In remote cabinet installations, the PCL-422 module
located with the communicator is powered by either an HSM2204 or an
HSM2300. Refer to the PCL-422 installation instructions for details.
Receiver/
Panel
• Sur-Gard System I Receiver, version 1.13+
• Sur-Gard System II Receiver, version 2.10+
Receiver
• Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
• Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
• Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver
• HS2016
• HS2032
Panel
• HS2064
• HS2128
P
I
RE
NSTALLATION
I
NSTALLATION
3G2080(R)
Cellular only
10.8-12.5 VDC
90mA @ 13.66V
400mA @ 12V
900MHz, 1800MHz, 2100MHz
-10°C to 55°C
5% ~ 93% relative humidity, non-condensing
100 × 150 × 15
310
Description
C
ONFIGURATION
C
7
TL2803G(R)
Internet and Cellular
120mA @ 13.66V
2dBi
100 × 150 × 15
320
ONFIGURATION