Ethernet Options; Cellular Receiver 1 Options - DSC TL2803GR Installation Manual

Hide thumbs Also See for TL2803GR:
Table of Contents

Advertisement

[114] Ethernet Receiver 2 UDP Remote Port
Default (0BF5/3061)
This section is used to program the port number used by Ethernet receiver 2. Set the value of this
port when your installation is located behind a firewall, and must be assigned a particular port
number as determined by your central station system administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[115] Ethernet Receiver 2 UDP Local Port
Default (0BF9/3065)
Use this section to program the value of the local outgoing port. You can set the value of this port
when your installation is located behind a firewall and must be assigned a particular port number
as determined by your network administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[116] Ethernet Receiver 2 Domain Name
Default ( )
Enter the Domain Name as 32 character ASCII.

Ethernet Options

[124] Ethernet Test Transmission Time
Default (9999)
Enter a 4 digit number (0000-2359) using the 24-hour clock format (HHMM) to set the test trans-
mission time of day. Valid range: 00 - 23 hours (HH) and 00 - 59 minutes (MM). Programming a
value of 9999 will disable the test transmission time.
NOTE: The internal date and time will automatically be programmed when the unit communi-
cates with the primary receiver.
[125] Ethernet Test Transmission Cycle
Default (000000)
This value represents the interval between test transmissions, in minutes. Valid range: 000000 -
999999 minutes. Once the unit has sent the initial periodic test transmission, all future test trans-
missions will be offset by the programmed number of minutes. See sections [026] - [029].
Table 13: Ethernet Test Transmission Interval
Test Transmission Interval
Programmed Minutes
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes
will disable test transmission.

Cellular Receiver 1 Options

[201] Cellular Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account
code is used when transmitting heartbeat signals to the central station receiver. Signals received
from the control panel will use the control panel account number. Valid range: 0000000001 -
FFFFFFFFFE. Programming all 0 or all F will cause a module configuration trouble (yellow LED
= 12 flashes).
[202] Cellular Receiver 1 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the cen-
tral station. Valid range: 000000 - 099999. Values are entered as leading 0 followed by the five
digit DNIS. Format is BCD.
NOTE: Each Ethernet/cellular receiver must be programmed with a unique DNIS.
HSPA(3G) Alarm Communicator Installation Manual
Daily
001440
Weekly
Monthly
010080
043200
32