[029] Cellular 2 Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See system test options (above) for
details on settings.
NOTE: The time interval (in minutes) between periodic tests is programmed in section [125]
(Ethernet) and section [225] (cellular).
[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC
Trouble on the system restores.
[037] System Panel Firmware Update Fail
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the sys-
tem firmware updated has failed.
Table 12: System Firmware Update Failure
Event
[037] System FW Update Fail
NOTE: The communicator will report ´System Update Fail´ only if the panel becomes offline
after a remote firmware update session has started.
[095] SA Incoming Local Port
Default (0000)
[096] SA Outgoing Local Port
Default (0000)
[097] SA Call Up IP
Default (000.000.000.000)
[098] SA Call Up Port
Default (0000)
[099] SA Password
Default (FFFFFFFF)

Ethernet Receiver 1 Options

[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account
code is used when transmitting heartbeat signals to the central station receiver. Signals received
from the panel will use the control panel account number. Valid range: 0000000001-
FFFFFFFFFE. Programming all 0 or all F will cause a module configuration trouble.
NOTE: If Ethernet receiver 1 and cellular receiver 1 are programmed as the same receiver (IP and
port number are identical), Ethernet receiver 1 account code will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialed Number Information Service (DNIS) is used in addition to the account code to identify
the communicator module at the central station. Valid range: 000000 - 099999. Value is entered as
a leading 0 followed by the 5 digit DNIS. Format is Binary Coded Decimal (BCD).
NOTE: Each Ethernet/cellular receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the communicator to operate in Unattended Mode.
HSPA(3G) Alarm Communicator Installation Manual
SIA
Identifier
LU
SIA
Contact
Reporting
ID
Code
Qualifier
0000
1
30
Contact
Contact
ID
ID
Event
Reporting
Code
Code
9
04
Contact
ID
User/Zone
003

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents