DSC HS2032 Installation Manual

Power neo series alarm control
Hide thumbs Also See for HS2032:

Advertisement

To download the full installation and user manuals and register your product, please visit:
www.DSC.com/m/29009812 or scan the QR code to the right.

Quick Setup

1
Plan
Plan the installation including all alarm detection devices,
zone expanders, keypads and other required modules.
2
Mount
Decide on a location for the alarm panel and secure it to the
wall using suitable mounting hardware.
3
Wire
Complete all wiring including modules, zones, bells/sirens,
telephone line connections and ground connections. Record
module serial numbers on page 19.
4
Power
Connect the battery and power up the system. The battery
must be connected.
5
Enroll
Hardwired: Wire the keypad to the Corbus, power up the
First
alarm panel then press any button on the keypad. Wireless:
Keypad
Wire the HSM2Host to the Corbus, then power up the alarm
panel and a wireless keypad. Press any button on the keypad to
enroll it. The HSM2Host is then enrolled on the alarm panel.
Alternately, enroll an RF keypad.
6
Enroll
[*][8][Installer Code][902] subsection [000]. Press [*] to
begin auto-enrollment. Module slots are automatically
modules
assigned. Use scroll keys to view slots. Change slot by typing a
2-digit number.
7
Enroll
[*][8][Installer Code][804] subsection [000]. Note: An
wireless
HSM2HOST or RF keypad must be enrolled first.
devices
8
Program
Basic programming: [*][8][installer code] [001]/[002]> Zone
Type/Zone Attribute [005]>[001] Partition 1 Timers: – Entry
Delay 1 – Entry Delay 2 – Exit Delay [301]>[001] Phone #1
[310]>[000] System Account Code.
9
Test
Test the panel completely to ensure that all features and
functions operate as programmed. – [901] Walk Test – [904]
[000] Wireless Placement Test.

Compatible Devices

Throughout this document, x in the model number represents the
operating frequency of the device as follows: 9 (912-919 MHz), 8
(868MHz), 4 (433MHz).
Table 1-1 Compatible Devices
Modules
Wireless keypads:
HS2LCDWFx
HS2LCDWFPx
Hardwired keypads with 2-way wireless
HS2LCDRFx
HS2LCDRFPx
integration module:
Hardwired keypads:
HS2LCD
HS2LCDP
HS2ICN
Touchscreen Keypad
HS2TCHP
2-way wireless integration module:
HSM2HOSTx
8-zone expander:
HSM2108
8-output expander:
HSM2208
Power supply:
HSM2300
4 high current output expander:
HSM2204
WARNING: This manual contains information on limitations regarding product use and function and information on
the limitations as to liability of the manufacturer. The entire manual should be carefully read.
PowerSeries Neo Alarm Control Installation Guide
HS2LCDWFPVx
HS2ICNRFx
HS2ICNRFPx
HS2ICNP
HS2LED
Alternate communicator:
3G2080E
3G2080RE
TL280E
TL280RE

Hardwired Devices

2-wire smoke detectors:
FSA-210x
FSA-210xT
y= A, B, or C
FSA-210xS
A: ULC listed models
FSA-210xST
B: UL listed models
FSA-210xLST
C: European and Australian models
4-wire smoke detectors:
FSA-410x
FSA-410xT
FSA-410xS
y= A, B, or C
FSA-410xST
A: ULC listed models
FSA-410xLST
B: UL listed models
C: European and Australian models
CO detectors:
CO-12/24
12-24SIR
FW-CO12

Wireless Devices

Wireless PG smoke detectors
Wireless PG smoke and heat detector
Wireless PG CO detector:
Wireless PG PIR motion detectors:
Wireless PG PIR + camera motion detector
Wireless PG curtain motion detector
Wireless PG dual tech motion detector
Wireless PG mirror motion detector
Wireless PG outdoor motion detector
Wireless PG glass break detector:
Wireless PG shock detector:
Wireless PG flood detector:
Wireless PG temperature detector (indoor use):
Outdoor temperature probe (requires PGx905)
Wireless PG keys:
Wireless PG panic key
Wireless PG 2-button key
Wireless PG sirens:
Wireless PG repeater:
Wireless PG door/window contacts:
Wireless PG door/window contact w/ AUX
Central Station Receivers
SG-System I, II, III, IV, 5
Enclosures
PC5003C, PC4050CR, PC4050CAR, CMC-1, PC4051C. Other enclosures are available to suit a variety
of system configurations.
TL2803GE
TL2803GRE
PCL-422
FSA-210xR
FSA-210xRT
FSA-210xRS
FSA-210xRST
FSA-210xLRST
FSA-410xR
FSA-410xRT
FSA-410xRS
FSA-410xRST
FSA-410xLRST
FW-CO1224
CO1224
PGx926
PGx916
PGx913
PGx904(P)
PGx934(P)
PGx924
PGx984(P)
PGx974(P)
PGx994
PGx912, PGx922
PGx935
PGx985
PGx905
PGTEMP-PROBE
PGx939
PGx929
PGx938
PGx949
PGx901
PGx911
PGx920
PGx975
PGx945

Advertisement

Table of Contents
loading

Summary of Contents for DSC HS2032

  • Page 1: Quick Setup

    To download the full installation and user manuals and register your product, please visit: www.DSC.com/m/29009812 or scan the QR code to the right. PowerSeries Neo Alarm Control Installation Guide Quick Setup Alternate communicator: 3G2080E TL2803GE 3G2080RE TL2803GRE TL280E PCL-422 Plan...
  • Page 2: Safety Instructions For Service Personnel

    PowerSeries Neo Installation Guide open the device yourself. Use authorized accessories only with this Safety Instructions for Service Personnel equipment. DO NOT leave and/or deposit ANY object on the top of the Warning: When using equipment connected to the telephone network, always follow the cabinet of this equipment! The cabinet as it is installed on the wall is not basic safety instructions provided with this product.
  • Page 3 Device Output Rating (12VDC) (mA) (mA) HS2016 AUX: 700mA. Subtract the listed rating for each keypad, expansion HS2016/HS2032/HS2064/HS2064 module and accessory connected to AUX or Corbus. At least HS2032 E/HS2128/HS2128 E 100mA must be reserved for the Corbus. HS2064 HS2LCD...
  • Page 4 PowerSeries Neo Installation Guide Capacitance Limits terminal, the negative side to GND. The AUX output is protected; if too much current is drawn from these terminals (wiring short) the output is An increase in capacitance on the Corbus affects data transmission and temporarily shut off until the problem is corrected.
  • Page 5 Table 1-5 Module Capacity Telephone Line Wiring Module HS2016 HS2032 HS2064/ HS2128/HS2128 E Wire the telephone connection terminals (TIP, Ring, T-1, R-1) to an RJ- HS2064 E 31x connector as indicated in the following diagram. For connection of HSM2108 8 Zone expander multiple devices to the telephone line, wire in the sequence indicated.
  • Page 6: Programming Methods

    PowerSeries Neo Installation Guide 3. Select an option to view or change its programming. To confirm that a module has been successfully enrolled, use Installer All programming options are numbered and can be accessed by navigating Programming section [903]. through the menu (LCD) or by keying in the program section number. For toggle options, the name of the option is displayed (LCD) or LEDs 1-8 are Enroll Wireless Devices illuminated (LED and ICON).
  • Page 7 PowerSeries Neo Installation Guide placed in common areas of the premises, such as points of entry or 4 – Bypass Enabled reception areas, where the ability to arm and disarm more than one 5 – Force Arm partition at a time is required. 6 –...
  • Page 8 PowerSeries Neo Installation Guide After 15 minutes without zone activity, the walk test terminates Table 1-7 : Trouble Indications automatically. To manually exit walk test mode, enter [901] again. Trouble 01 – Service Required: Viewing the Event Buffer [01] Bell Circuit Trouble: The bell circuit is open. The event buffer contains logs of events that have occurred on the alarm [02] RF Jam: The HSM2HOSTx has detected an RF Jam condition.
  • Page 9 PowerSeries Neo Installation Guide Trouble 07 – Device Tampers: Trouble 10 – Module Tamper: [01] Zone 001 - 128 Tamper: A wireless or hardwired zone configured for DEOL [01] HSM2HOSTx Tamper. operation is in tamper. [02] Keypad 01 - 16 Tamper. [02] Keypad 01 - 16 Tamper: A hardwired or wireless keypad is in tamper.
  • Page 10 24 hours INCERT [Belgium] HS2016: 2083333 Note: For T 014 compliance (INCERT certification), only 14Ah (2x7Ah) batteries were tested and are accepted for INCERT HS2032: 1388888 certified systems. HS2064/HS2128: 1052631 Maximum standby time: 24 hours (with 14Ah battery and Aux...
  • Page 11 PowerSeries Neo Installation Guide Proximity tag support PGM scheduling Quick arming User, partition, module, zone and system labels Soak test Programmable system loop response Keypad and panel software versions viewable through keypad Doorbell zone type Low battery PGM type - 11 -...
  • Page 12 Programming Directory This section provides a list of all available programming options in numerical order. To program, access Installer Programming mode by keying in [*][8] [Installer Code]. Use the scroll keys < > to navigate through the menus or jump directly to a specific section by keying in a section number and pressing [*].
  • Page 13 PowerSeries Neo Installation Guide 02 – Timed Output ✔ 204 – Follower-Zones 25-32 201- 216 Zone Follow Zones 1-128 1 – Chime On Opening 01 – True Output ✔ 205 – Follower-Zones 33-40 04 – Fire Alarm 2 – Chime On Closing 206 –...
  • Page 14 PowerSeries Neo Installation Guide 1 – Ready LED Flash for Force Thursday 202 – Open/Close Events 2 301 Phone Number Programming 01 – Automatic Closing ✔ Friday 001 – 004 Phone Number 1 -4 02 – Automatic Disarm ✔ 2 – Not Used Saturday Programming (DFFF...32-digit) 3 –...
  • Page 15: Dls Programming

    Failure ✔ Restore HS2064 Models () 2 – Receiver 2 004 – Periodic Test Transmission 352 – Alternate Communicator 2 HS2032 Models () 3 – Receiver 3 Time of Day (9999) 01 – Alternate Comm. HS2016 Models () 4 – Receiver 4 011 –...
  • Page 16 PowerSeries Neo Installation Guide 12 – Holiday 4 201 – Interval 614 – Number of Rings to Answer 07 – System Test 410 Automatic DLS Options 001 – Automatic DLS Toggle 2 Start Time (0000) (00) 09 – Night Arm Options 402 –...
  • Page 17: Module Programming

    PowerSeries Neo Installation Guide – DLS Access Code (6-digit 01– Panel High Charge Current (SA ✔ )(FRA ✔ ) decimal) (UK ✔ ) – Partition Entry Delay (000-255 sec.) 010 – HSM2204 Battery Settings – Partition Exit Delay (000-255 01 – HSM2204 1 High Charge Current (SA ✔...
  • Page 18 PowerSeries Neo Installation Guide Zone Record Zone Label Location Type Attribute Zone Label Location Type Attribute - 18 -...
  • Page 19: System Account Code

    PowerSeries Neo Installation Guide Zone Label Location Type Attribute Zone Label Location Type Attribute Module Record Module Type Slot Serial Number Module Type Slot Serial Number Wireless Device Record Device Type Zone Serial Number Device Type Zone Serial Number Installer-Defined Access Codes 001 –...
  • Page 20 PowerSeries Neo Installation Guide Make sure that all border doors and windows are easily opened. Ensure that Locating Detectors and Escape Plan they are not painted shut, and that their locking mechanisms operate smoothly. If opening or using the exit is too difficult for children, the elderly or han- The following information is for general guidance only and it is recommended that local dicapped, plans for rescue should be developed.
  • Page 21 Optional feature implemented for EN 50131 Grade 2: Removal from mounting tamper detection for non wire-free components The model HS2128, HS2064, HS2032, HS2016 Control Panel has been certified by Telefication according to EN50131-1:2006 +A1:2009, EN50131-3:2009, EN50131-6:2008 (Type A) and EN50136-1:1997 (ATS2) for Grade 2, Class II.
  • Page 22 Where appropriate, additional internal audible indications (PG8911 indoor sirens) should be provided so that persons within a building are informed that the HS2128, HS2064, HS2032, HS2016 are due to be set. Additional keypads should be provided, where appropriate, so that if the alarm panel is set there are means available locally within the supervised premises to unset the system.
  • Page 23 SIA False Alarm Reduction Installations: Quick Reference Minimum required system consists of one Control unit model HS2128 or HS2064 or HS2032 or HS2016 and any one of the compatible listed keypads: HS2LCDRF9, HS2LCDRFP9, HS2ICNRF9, HS2ICNRFP9, HS2LCD, HS2LCDP, HS2ICN, HS2ICNP, HS2LED HS2TCHP.
  • Page 24 PowerSeries Neo Installation Guide SIA Feature Programming Comments Range/Default Requirement Section Range:45- 255 Exit Time Required seconds Access to Entry and Exit delays and Bell Time Out for the system. [005]>[001], option 3 (programmable) Default: 60 sec. Exit Delay Restart Opening a Delay zone door after it has already been opened and closed during an exit delay restarts the Default: Enabled Required...
  • Page 25 DSC. Custom products are only warranted to the extent that Out of Warranty Repairs they do not function upon delivery. In such cases, DSC can replace or credit at its option. Digital Security Controls will at its option repair or replace out-of-warranty products which are returned to its factory according to the following conditions.
  • Page 26 PowerSeries Neo Installation Guide While each transmitting device has a low battery monitor which identifies when the Security and Insurance batteries need to be replaced, this monitor may fail to operate as expected. Regular Regardless of its capabilities, an alarm system is not a substitute for property or life testing and maintenance will keep the system in good operating condition.
  • Page 27 EULA, even if this EULA is deemed to be a modification of any previous arrangement or contract. If You do not agree to the terms of this EULA, DSC is unwilling to license the SOFTWARE PRODUCT to You, and You have no right to use it.
  • Page 28 Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative. © 2016 Tyco Security Products All Rights Reserved. Tech Support: 1-800-387-3630 (Canada & U.S.) or 905-760-3000 www.dsc.com...

Table of Contents