Ratings Compatibility; Pre Installation Configuration - DSC 3G2060 Installation Manual

Internet/hspa alarm communicator
Table of Contents

Advertisement

Pre Installation Configuration

Ratings Compatibility

Table 5: Communicator Ratings
Model
Power Supply Ratings
• Input Voltage
Current Consumption
• Standby Current
• Alarm (Transmitting) Current
• Operating Frequency
• Typical Antenna Gain
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with bracket
Table 6: Compatible Receivers, and Panels
Communicator
3G2060
TL2603G/TL260
NOTE: Enter [*][8][Installer Code][900] at keypad to view the Panel Version number.
P
Remote Programming via DLS 5:
Before programming, you will require your network's Public IP Address and Public listening port
for incoming DLS 5connections. You must send an SMS message to the unit, therefore, you must
know the phone number assigned to the SIM.
1. Run the DLS 5 software on your computer. If required, download the DLS 5 software from DSC:
http://www.dsc.com/index.php?n=library#self.
2. Create an account for the Panel/Communicator, select the Communicator type (e.g., SMS -
3G2060) and enter all relevant information under SMS section, including the Communicator's
cellular telephone number.
3. All available Communicator and panel options can be configured in the DLS 5 account. Refer
to Panel Installation Guide and Communicator Manual for detailed programming information.
Also, refer to your DLS 5 manual and Help file.
4. When you have finished programming the account, click Global Download and choose SMS as
Connection Type. Click OK.
5. DLS 5 will generate the required text for the SMS message. This message has the Public IP and
Port Number of the DLS Server to allow the Communicator to link up with your computer.
Type the SMS message in to your cell phone and send to the Communicator's cellular phone
number. Then Click OK.
6. The SMS message will trigger the unit to establish a connection to your DLS 5 software. New
programming of the Communicator will be downloaded to the unit remotely via cellular or
3G2060
Cellular only
90mA @ 13.66V
100 × 150 × 15
310
Receiver/
Panel
• SG-System I Receiver, version 1.13+
• SG-System II Receiver, version 2.10+
Receiver
• SG-DRL3-IP, version 2.30+ (for SG-System III Receiver)
• SG-DRL4-IP version 1.20+ (for SG-System IV Receiver)
• SG-DRL5-IP version 1.00+ (for SG-System 5 Receiver)
• Power Series PC1616, version 4.5+
Panel
• Power Series PC1832, version 4.5+
• Power Series PC1864, version 4.5+
I
RE
NSTALLATION
3G Alarm Communicator Installation Manual
TL2603G
Ethernet and Cellular
Nominal 12 VDC:
The panel Bell output shall be derated:
700mA - (Communicator mA) = (derated Bell output).
120mA @ 13.66V
400mA @ 12V
850MHz, 1900MHz
2dBi
32°F - 120°F (0°C - 49°C)
5% ~ 93% relative humidity, non-condensing
100 × 150 × 15
Description
C
ONFIGURATION
3
Ethernet only
100mA @ 13.66V
320
TL260
N/A
N/A
100 × 150 × 15
290