Unattended mode is used when a receiver is not available and the unit is required to perform DLS
sessions. Typically used where the customer programs the control panel daily due to access control
and still wants to receive alarms without buying extra hardware (receiver) or software.
NOTE: When a valid IP address has been programmed, Ethernet receiver 1 is enabled and will
communicate events over the Ethernet channel.
Ethernet receiver 1 and cellular receiver 1 may be configured to communicate to the same central
station receiver. To configure the device to operate using this common receiver mode functional-
ity, program Ethernet receiver 1 and cellular receiver 1, IP address and port number with identical
values.
NOTE: When operating in common receiver mode, Ethernet receiver 1 account code will be used
for Ethernet and cellular.
[104] Ethernet Receiver 1 UDP Remote Port
Default (0BF5/3061)
This section determines the UDP remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 UDP Local Port
Default (0BF4/3060)
Use this section to set the value of the UDP local outgoing port. Set the value of this port when
your installation is located behind a firewall and must be assigned a particular port number as
determined by your central station system administrator. Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default ( )
Enter the domain name as 32 ASCII characters.

Ethernet Receiver 2 Options

[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. The account
code is used when transmitting heartbeat signals to the central station receiver. Signals received
from the control panel will use the control panel account number. Valid range: 0000000001-
FFFFFFFFFE. Programming all 0 or all F will cause a module configuration Trouble (yellow
LED=12 flashes).
NOTE: If both Ethernet receiver 2 and cellular receiver 2 are the same receiver (IP and port num-
ber are identical), Ethernet receiver 2 account will be used for Ethernet and cellular.
[112] Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the cen-
tral station. Valid range: 000000 - 099999. Value is entered as leading 0 followed by the 5-digit
DNIS. Format is BCD.
NOTE: Each Ethernet/cellular receiver must be programmed with a unique DNIS.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable Ethernet.
Enter the Ethernet receiver 2 IP address. This address will be provided by your central station sys-
tem administrator. Format is 4 fields, each field is a 3-digit decimal. Valid range: 000-255.
NOTE: When a valid IP address has been programmed, Ethernet receiver 2 is enabled and will
communicate events over the Ethernet channel.
Ethernet receiver 2 and cellular receiver 2 may be configured to communicate to the same central
station receiver.
To configure the device to operate using this common receiver mode functionality, program the
Ethernet receiver 2 and cellular receiver 2, IP address and port number with the same values.
When operating in common receiver mode the Ethernet receiver 2 account code will be used for
communications over Ethernet and cellular.
NOTE: Do not program Ethernet receiver 1 and Ethernet receiver 2 to communicate to the same
receiver.
HSPA(3G) Alarm Communicator Installation Manual