Ratings Compatibility

Table 1: Communicator Ratings
Model
Power Supply Ratings
Input Voltage
Current Consumption
Standby Current
Alarm (Transmitting) Current
Operating Frequency
Typical Antenna Gain
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with bracket
Table 2: Compatible Receivers, and Panels
Communicator
3G2080(R)
TL2803G(R)
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Products or components of products, which perform communications functions only shall comply
with the requirements applicable to communications equipment as specified in UL60950 or CAN
CSA C22.2. No. 60950-1, Information Technology Equipment - Safety - Part 1: General Require-
ments. Where network interfaces are external to the control unit or receiver, compliance to CAN
CSA C22.2. No. 60950-1 is adequate. Such components include, but are not limited to: hubs; rout-
ers; NIDs; third-party communications service providers; DSL modems; and cable modems.
C
OMMUNICATOR
This HSPA(3G)/dual-path alarm communicator shall be installed by service persons only (service
person is defined as a person having the appropriate technical training and experience necessary to
be aware of hazards to which that person may be exposed to in performing a task and can also take
measures to minimize the risks to that person or other persons). The Communicator shall be
installed and used within an environment that provides the pollution degree max 2, overvoltages
category II, in non-hazardous, indoor locations only. This manual shall be used with the installa-
tion manual of the panel which is connected to the communicator. All instructions specified within
the panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during instal-
lation.

Installing the Ethernet Cable(TL2803G(R) Only)

A Category 5 (CAT 5) Ethernet cable must be run from a source with Internet connectivity to the
communicator module, inside the panel. The communicator end of the cable must be terminated
with an RJ45 plug, which will connect to the communicator's RJ45 jack after the communicator is
installed. All requirements for installation of CAT5 Ethernet cable must be observed for correct
operation of the communicator, including, but not limited to, the following:
Power is supplied from the panel's PC-Link header or a PCL-422 module in
remote cabinet installations. In remote cabinet installations, the PCL-422 module
located with the communicator is powered by either an HSM2204 or an
HSM2300. Refer to the PCL-422 installation instructions for details.
Receiver/
Panel
• Sur-Gard System I-IP Receiver, version 1.13+
• Sur-Gard System II Receiver, version 2.10+
Receiver
• Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
• Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
• Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
• HS2016
• HS2032
Panel
• HS2064
• HS2128
I
NSTALLATION
HSPA(3G)/Dual Alarm Communicator Installation Manual
3G2080(R)
Cellular only
10.8-12.5 VDC
90mA @ 13.66V
400mA @ 12V
850MHz, 1900MHz
14°F to 131°F (-10°C to 55°C)
5% ~ 93% relative humidity, non-condensing
100 × 150 × 15
310
Description
C
4
TL2803G(R)
Internet and Cellular
120mA @ 13.66V
2dBi
100 × 150 × 15
320
ONFIGURATION